Solution Type Problem Resolution Sure Solution 1269395.1 : Sun Fire[TM] V1280, E2900, Netra[TM] 1280, and 1290 Servers: IB_SSC fails POST after "Not enough memory" message
When POST encounters "Not enough memory to allocate buffer of XXXXXX bytes." the next "Excluded unusable, unlicensed, failed or disabled board: /N0/IB6" may be just a side effect that an SC reboot will fix. In this Document
Applies to:Sun Fire V1280 Server - Version Not Applicable and laterSun Fire E2900 Server - Version Not Applicable to Not Applicable [Release N/A] Sun Netra 1280 Server - Version Not Applicable to Not Applicable [Release N/A] Sun Netra 1290 Server - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. SymptomsThe "showlogs" command on the SC or the domain's "lw8" messages show these log entries: 11/14/10 2:46:39 AM Domain Reboot A: Initiating keyswitch: on, domain A.
11/14/10 2:46:39 AM Domain Reboot A: Initiating keyswitch: on, domain A. 11/14/10 2:47:16 AM Not enough memory to allocate buffer of 431300 bytes. 11/14/10 2:47:22 AM Excluded unusable, unlicensed, failed or disabled board: /N0/IB6 11/14/10 2:47:22 AM No usable Io board in domain. 11/14/10 2:47:22 AM Reboot failed. 11/14/10 2:51:20 AM Domain Shell - A: poweroff: Initiating keyswitch: off, domain A.
......
{/N0/IB6/P0} Unknown {/N0/IB6/P1} Unknown ...... ChangesThis happens typically after a long uptime of the SC and frequent reboots of the domain. CauseThe SC's memory is too fragmented to allocate the required amount of memory. SolutionReboot the SC to clear the memory fragmentation. lom> resetsc
Because the degree of fragmentation cannot be determined, there is no recommendation when to reboot the SC proactively. Attachments This solution has no attachment |
||||||||||||||||||
|