Solution Type Problem Resolution Sure Solution 1003661.1 : How to recover when a Sun Fire[TM]E2900, V1280 or Netra[TM] 1280 has an incompatible RTOS and ScApp
PreviouslyPublishedAs 205172 Applies to:Sun Fire E2900 Server - Version Not Applicable and laterSun Netra 1290 Server - Version Not Applicable and later Sun Netra 1280 Server - Version Not Applicable and later Sun Fire V1280 Server - Version Not Applicable and later All Platforms SymptomsIt is possible when upgrading the firmware in a V1280/E2900 or Netra 1280/1290 platform using the 'lom -G' command to end up with a mismatch of RTOS and ScApp.
To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - SPARC Legacy Servers
ChangesThe 'lom -G' command is utilized to upgrade ScApp (otherwise known as lom or generically as the firmware). CauseThis usually happens as a result of following only parts of the upgrade instructions, or not having read the entire upgrade procedure first. If you follow the instructions from the lom -G command and do a resetsc immediately after applying the sgsc.flash image, you will end up with a mismatch and a very unhappy system controller. IMPORTANT NOTES: EXAMPLE of the system firmware mismatch by not following the correct procedure
At this point, the SC is unusable, and does NOT start up into ScApp. If the IB-SSC ethernet connection is not configured, this is a little trickier since you will have to configure the IB-SSC ethernet connection from the RTOS. If you have the IB-SSC ethernet connection configured, and if you have a host on the SC network which has the firmware, you can recover as in an internally documented procedure. SolutionResolving this issue requires that you open a service request and speak to an Oracle Support Engineer. The issue must be validated, and due to the complex nature of the resolution an Oracle Support Engineer will need to guide you through this resolution. That engineer's task in resolving this issue might be made easier if they are able to utilize Shared Shell to remotely access this host and perform the procedure to resolve the mismatch. This type of remote access is not always possible, but it's worth validating if this is an option. Please remember to specify that you utilized this document ID when opening the Service Request. The service engineer can pick up at this point and resolve the issue utilizing the internally documented process.
Support engineer instructions for resolving this issue. If needed assist the customer via Shared Shell in order to avoid dispatching a field resource on site for this resolution. Enter URL : Enter the absolute path name to the directory where the SC can find the firmware (See below in BOLD). Enter URL : ftp://root:passwd@129.156.210.160//var/tmp/114525-02 Rebooting the SC to automatically complete the upgrade. Software Reset... (#) SYSTEM CONTROLLER(SC) POST 39 2004/04/19 19:20 PSR = 0x044010e5 PCR = 0x04004000 Memory size = 32MB Basic sanity checks done. Skipping POST ... ERI Device Present Getting MAC address for SSC1 Using SCC MAC address MAC address is 0:3:ba:19:91:1e Hostname: v4u-v1280a-sc1-gmp03 Address: 129.156.210.161 Netmask: 255.255.248.0 Attached TCP/IP interface to eri unit 0 Attaching interface lo0...done Gateway: 129.156.208.1 interrupt: 100 Mbps full duplex link up Flashupdate Connecting to 129.156.210.160... Transferring sgrtos.flash via FTP : 692552 Validating RTOS flash image... Updating flashprom sectors at address 0x20000000: 11/11 = 100% ok Connecting to 129.156.210.160... Transferring sgsc.flash via FTP : 6349779 Validating ScApp flash image... Updating flashprom sectors at address 0x36000000: 97/97 = 100% ok Software Reset... (#) SYSTEM CONTROLLER(SC) POST 41 2004/08/18 09:31 PSR = 0x044010e5 PCR = 0x04004000 Memory size = 32MB Basic sanity checks done. Skipping POST ... ERI Device Present Getting MAC address for SSC1 Using SCC MAC address MAC address is 0:3:ba:19:91:1e Hostname: v4u-v1280a-sc1-gmp03 Address: 129.156.210.161 Netmask: 255.255.248.0 Attached TCP/IP interface to eri unit 0 Attaching interface lo0...done Gateway: 129.156.208.1 interrupt: 100 Mbps full duplex link up Copyright 2001-2004 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Sun Fire System Firmware RTOS version: 41 ScApp version: 5.18.1 Build_01 SC POST diag level: off The date is Monday, April 25, 2005, 10:37:49 AM GMT. Mon Apr 25 10:37:50 v4u-v1280a-sc1-gmp03 lom: Boot: ScApp 5.18.1, RTOS 41 Mon Apr 25 10:37:58 v4u-v1280a-sc1-gmp03 lom: Caching ID information Mon Apr 25 10:37:59 v4u-v1280a-sc1-gmp03 lom: Clock Source: 75MHz Mon Apr 25 10:38:03 v4u-v1280a-sc1-gmp03 lom: /N0/PS0: Status is OK Mon Apr 25 10:38:04 v4u-v1280a-sc1-gmp03 lom: /N0/PS1: Status is OK Mon Apr 25 10:38:04 v4u-v1280a-sc1-gmp03 lom: /N0/PS2: Status is OK Mon Apr 25 10:38:05 v4u-v1280a-sc1-gmp03 lom: /N0/PS3: Status is OK Mon Apr 25 10:38:05 v4u-v1280a-sc1-gmp03 lom: Chassis is in single partition mode. Mon Apr 25 10:39:32 v4u-v1280a-sc1-gmp03 lom: /N0/FT0, fan speed, Low (4,1) Mon Apr 25 10:39:37 v4u-v1280a-sc1-gmp03 lom: Starting telnet server ... Enter Password: Mon Apr 25 10:39:52 v4u-v1280a-sc1-gmp03 lom: FT0/FAN6 Faulty, replacement required Mon Apr 25 10:39:52 v4u-v1280a-sc1-gmp03 lom: FULL-COOLING ENGAGED: turning fans high Mon Apr 25 10:39:52 v4u-v1280a-sc1-gmp03 lom: /N0/FT0, sensor status, fan failure (7,4) Mon Apr 25 10:40:08 v4u-v1280a-sc1-gmp03 lom: /N0/FT0, fan speed, High (4,2) Connected. # # PROBLEM - SSC1 ETHERNET PORT NOT CONFIGURED Enter URL : ftp://root:passwd@129.156.210.160//var/tmp/114525-02 Connection has timed out or the remote host is unreachable. Enter URL : flashupdate: failed, /sgrtos.flash: is not a valid url Enter URL : Note: Attempting to recover using 'lom -G' # lom -G /var/tmp/114525-02/sgrtos.flash This program will replace LOM firmware with version 5.11.3 <--- CR 6266849 Are you sure you want to continue Enter 'C' and return to Continue or anything else to Terminate C Programming LOM failed with error: Connection timed out # Enter URL :
Hardware Reset... (#) SYSTEM CONTROLLER(SC) POST 39 2004/04/19 19:20 PSR = 0x044010e5 PCR = 0x04004000 Memory size = 32MB Basic sanity checks done. Skipping POST ... ERI Device Present Getting MAC address for SSC1 Using SCC MAC address MAC address is 0:3:ba:19:91:1e Using DHCP to configure network interface Attached TCP/IP interface to eri unit 0 Attaching interface lo0...done Initializing DHCP libraries interrupt: 100 Mbps full duplex link up Initiating DHCP negotiations for eri0 dhcpcBind() failed: S_taskLib_NAME_NOT_FOUND Copyright 2001-2004 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. <------------------Hit CTRL-a here Sun Fire System Firmware RTOS version: 39 ScApp version: 5.18.1 Build_01 The RTOS revision is too old for this version of ScApp. ScApp version 5.18.1 requires RTOS version 40 butTask not found spawning new shell. -> -> setBootFlags(0x10) value = 8 = 0x8 -> <------------------Hit CTRL-x here Software Reset... (#) SYSTEM CONTROLLER(SC) POST 39 2004/04/19 19:20 PSR = 0x044010e5 PCR = 0x04004000 Memory size = 32MB Basic sanity checks done. Skipping POST ... ERI Device Present Getting MAC address for SSC1 Using SCC MAC address MAC address is 0:3:ba:19:91:1e Using DHCP to configure network interface Attached TCP/IP interface to eri unit 0 Attaching interface lo0...done Initializing DHCP libraries interrupt: 100 Mbps full duplex link up Initiating DHCP negotiations for eri0 dhcpcBind() failed: S_taskLib_NAME_NOT_FOUND -> -> ifMaskSet("eri0", 0xfffff800) value = 0 = 0x0 -> ifAddrSet("eri0", "129.156.210.161") value = 0 = 0x0 -> ifFlagSet("eri0", 0x8063) value = 0 = 0x0 -> routeAdd("0.0.0.0", "129.156.208.1") value = 0 = 0x0 -> hostAdd("admin-ws", "129.156.186.23") value = 0 = 0x0 -> ping "admin-ws",1 admin-ws is alive value = 0 = 0x0 -> updateBootFlashURL (ftp://admin-ws/pub/114525-02/sgrtos.flash) Note: The admin-ws is set up for anonymous ftp Connecting to admin-ws... Transferring sgrtos.flash via FTP : 692552 Validating RTOS flash image... Updating flashprom sectors at address 0x20000000: 11/11 = 100% ok value = 0 = 0x0 -> setBootFlags(0x8) value = 16 = 0x10 -> reboot Software Reset... (#) SYSTEM CONTROLLER(SC) POST 41 2004/08/18 09:31 PSR = 0x044010e5 PCR = 0x04004000 Memory size = 32MB Basic sanity checks done. Skipping POST ... ERI Device Present Getting MAC address for SSC1 Using SCC MAC address MAC address is 0:3:ba:19:91:1e Using DHCP to configure network interface Attached TCP/IP interface to eri unit 0 Attaching interface lo0...done Initializing DHCP libraries interrupt: 100 Mbps full duplex link up Initiating DHCP negotiations for eri0 dhcpcBind() failed: S_taskLib_NAME_NOT_FOUND Copyright 2001-2004 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Sun Fire System Firmware RTOS version: 41 ScApp version: 5.18.1 Build_01 SC POST diag level: off The date is Monday, April 25, 2005, 5:42:51 AM PDT. Mon Apr 25 05:42:52 noname.example.com lom: Boot: ScApp 5.18.1, RTOS 41 Mon Apr 25 05:42:54 noname.example.com lom: SBBC Reset Reason(s): Power On Reset Mon Apr 25 05:42:54 noname.example.com lom: Initializing the SC SRAM Mon Apr 25 05:43:00 noname.example.com lom: Caching ID information Mon Apr 25 05:43:01 noname.example.com lom: Clock Source: 75MHz Mon Apr 25 05:43:06 noname.example.com lom: /N0/PS0: Status is OK Mon Apr 25 05:43:06 noname.example.com lom: /N0/PS1: Status is OK Mon Apr 25 05:43:07 noname.example.com lom: /N0/PS2: Status is OK Mon Apr 25 05:43:08 noname.example.com lom: /N0/PS3: Status is OK Mon Apr 25 05:43:08 noname.example.com lom: Chassis is in single partition mode. Mon Apr 25 05:43:11 noname.example.com lom: NOTICE: /N0/FT0 is powered off Mon Apr 25 05:43:12 noname.example.com lom: Cold boot detected: recovering active domains
Domain: A keyswitch on