2281806.1 |
Device ssd0 failed to power up. |
2017-09-18
|
1984183.1 |
IO PRIM_FAN and SEC_FAN Tray Failure on Sun Fire V890/V880 Server |
2016-06-24
|
1966319.1 |
Fatal PCI UE Error |
2017-04-05
|
1961470.1 |
Sun[TM] Remote System Control 2.2.3 rscadm command fails with 'fatal: relocation error:' |
2018-03-30
|
1935506.1 |
V480 Fan Not Working |
2017-04-05
|
1900988.1 |
SunFire V880 Panic on boot qlc@2 fail |
2017-04-05
|
1671062.1 |
Server Not Powering Up Fan/fantray Over-temperature failure |
2018-02-16
|
1591230.1 |
Diagnosing iostat Hard Errors on SPARC Servers DVD ROM |
2018-02-15
|
1566936.1 |
Sun Fire V480, V490, V880, V880z and V890 Flash PROM device in this system cannot be reprogrammed |
2018-02-16
|
1523775.1 |
V880 Crashed due to a disk failure |
2018-02-16
|
1516187.1 |
"Eject" button does not work on internal DAT72 drive. |
2018-02-16
|
1377558.1 |
Unable to write SSC050 device Failures During Boot/Shutdown (OBDIAG Failures) |
2018-02-15
|
1336755.1 |
V880/V890 Internal disk failure |
2018-02-15
|
1018924.1 |
Time of Day (TOD) drifts 2 or more seconds per day |
2013-02-20
|
1018551.1 |
picld reports "ERROR running psvc_check_temperature_policy_0 on CPUx_DIE_TEMPERATURE_SENSOR" |
2017-03-01
|
1011987.1 |
Error message - cannot load module 'pm', undefined symbol 'pm_enqueue_notify_others' |
2018-02-16
|
1011275.1 |
ERROR - gpio driver not installed / rscadm: Unable to reset RSC hardware |
2013-02-20
|
1010409.1 |
Sun[TM] Remote System Control 2.2 GUI complains about needing Java[TM] 1.3.0 or later |
2018-02-15
|
1010343.1 |
Sun Fire[TM] V880 server error: fru:Device busy |
2018-02-15
|
1009713.1 |
How to solve panic "Couldn't load stub module misc/pcicfg.e" on Sun Fire[TM] V880/V890 |
2018-02-15
|
1009467.1 |
How to clear faults in FMA after component replacement on Sun Fire[TM] servers. |
2017-02-02
|
1009409.1 |
How to configure RSC modem port for dial-in. |
2018-02-15
|
1009167.1 |
Loss of RSC console input/output on Sun Fire[TM] V480/V880 post upgrading OBP to 4.15.x or setting service-mode? to true |
2018-02-16
|
1009128.1 |
Solaris [TM] 9 on Sun Fire [TM] v880: prtdiag crashes with a segmentation fault after installing libpsvc patch 113574-08 |
2018-02-16
|
1008719.1 |
Resolving Hard Hang Problems on Sun Ultra Servers |
2016-04-15
|
1008187.1 |
Sun Fire [TM] V880 OBP and DPM firmware mismatch may cause false obdiag onboard fcal controller failures |
2018-02-15
|
1007842.1 |
Sun Fire[TM] V480/V880: Fatal Reset diagnostic output is not captured by the RSC card |
2018-02-15
|
1007782.1 |
Dynamic Reconfiguration or hot plug problems on a QGE HBA (4444A). |
2018-01-03
|
1007580.1 |
Sun Fire[TM] V880 or V480 firmware: Unable to Flashupdate: "ERROR: system security set: system firmware was not modified" |
2018-02-16
|
1006615.1 |
Sun[TM] GigaSwift Ethernet (ce) performance slow. |
2017-07-11
|
1003665.1 |
Sun Fire[TM] V880 with low OpenBoot[TM] Prom will not print out location of failed dimms |
2018-02-16
|
1003560.1 |
Solaris[TM]: What USB devices are supported on SPARC Workstations and Entry Level Servers |
2017-06-06
|
1003511.1 |
Solaris[TM] 8 and 9 Operating System: sbd warnings in /var/adm/messages on the Sun Fire[TM] V880 |
2018-02-16
|
1003144.1 |
Sun Fire[TM] 880: SCSI error with luxadm download for onboard FCAL firmware |
2013-02-20
|
1003118.1 |
Autonegotiation does not work between Sun[TM] Gigabit Ethernet (GBE) cards and Cisco 4003 fiber linecards |
2017-07-11
|
1002463.1 |
Sun Fire[TM] V480, V490, V880 and V890 system with RoHS RSC, part number 501-7314, emits "Unrecognized SC type, assuming 5016767" or give error "unable to find RSC serial device" while doing flashupgrade |