Asset ID: |
1-72-1961470.1 |
Update Date: | 2018-03-30 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1961470.1
:
Sun[TM] Remote System Control 2.2.3 rscadm command fails with 'fatal: relocation error:'
Related Items |
- Sun Fire 280R Server
- Sun Fire V480 Server
- Sun Fire V890 Server
- Sun Fire V880 Server
- Sun Fire V880z Visualization Server
- Sun Fire V490 Server
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-Vx80
|
In this Document
Created from <SR 3-10113359331>
Applies to:
Sun Fire 280R Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V490 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V480 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V880 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V880z Visualization Server - Version All Versions to All Versions [Release All Releases]
Oracle Solaris on SPARC (64-bit)
Symptoms
Problem seen while trying to configure RSC software, we get the error below.
We have removed/re-installed both the v2.2.2 and v2.2.3 packages but the same error on each when running the rsc-control, and rscadm.
Changes
Configuring RSC card with older Older version of the SUNWrsc patch 119380-01 or 119380-02
Cause
OS: Solaris 8 also seen with Solaris 9
rscadm fails with 'fatal: relocation error:' on adding Patch 119380-02
# ./rscadm help
rscadm: fatal: relocation error: file rscadm: symbol priocntl: referenced symbol not found
#
# pkginfo | egrep rsc
system SUNWrsc Remote System Control
system SUNWrscd Remote System Control User Guide
system SUNWrscj Remote System Control GUI
# pkginfo -l SUNWrsc
PKGINST: SUNWrsc
NAME: Remote System Control
CATEGORY: system
ARCH: sparc
VERSION: 2.2.3,REV=2005.01.18 =======>>>>>>> Installed Older version of the SUNWrsc path # 119380-01 or 119380-02
BASEDIR: /
VENDOR: Sun Microsystems, Inc.
DESC: Sun Remote System Control system software
PSTAMP: easy20050118163608
INSTDATE: Jan 12 2015 15:47
HOTLINE: Please contact your local service provider
STATUS: completely installed
FILES: 70 installed pathnames
15 shared pathnames
33 directories
6 executables
10507 blocks used (approx)
#
Known Issue with older version of the RSC adm package bundle explained in the below bug
Bug 15353214 : SUNBT6476680 RSCADM FAILS WITH 'FATAL: RELOCATION ERROR:' ON ADDING PATCH 119380
Solution
Install latest Patch bundle release 119380-06 Sun Remote System Control 2.2.3 .
Attachments
This solution has no attachment