Solution Type  Problem Resolution Sure

Solution  2281806.1 :   Device ssd0 failed to power up.  


Related Items
  • Sun Fire 280R Server
  •  
  • Sun Fire V480 Server
  •  
  • Sun Fire V890 Server
  •  
  • Sun Fire V880 Server
  •  
  • Sun Fire V490 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-Vx80
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-15145995071>

Applies to:

Sun Fire 280R Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V480 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V490 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V880 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V890 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

AVAILABLE DISK SELECTIONS:
       0. c1t0d0 <SUN72G cyl 14087 alt 2 hd 24 sec 424>
          /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w2100000c509933e3,0
       1. c1t1d0 <drive not available>
          /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000004cf6ba58e,0

Changes

 

Cause

device failed to power up, these messages are seen in /var/adm/messages

Jun 18 00:41:38 domainname genunix: [ID 405830 kern.warning] WARNING: Device ssd0 failed to power up.
Jun 18 00:41:38 domainname genunix: [ID 749148 kern.warning] WARNING: Please see your system administrator or reboot.
Jun 18 00:41:43 domainname genunix: [ID 405830 kern.warning] WARNING: Device ssd0 failed to power up.
Jun 18 00:41:43 domainname genunix: [ID 749148 kern.warning] WARNING: Please see your system administrator or reboot.
Jun 18 00:41:43 domainname scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000004cf6ba58e,0 (ssd0):
Jun 18 00:41:43 domainname offline
Jun 18 00:41:48 domainname genunix: [ID 405830 kern.warning] WARNING: Device ssd0 failed to power up.
Jun 18 00:41:48 domainname genunix: [ID 749148 kern.warning] WARNING: Please see your system administrator or reboot.
Jun 18 00:41:53 domainname genunix: [ID 405830 kern.warning] WARNING: Device ssd0 failed to power up.
Jun 18 00:41:53 domainname genunix: [ID 749148 kern.warning] WARNING: Please see your system administrator or reboot.
Jun 18 00:41:53 domainname scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000004cf6ba58e,0 (ssd0):
Jun 18 00:41:53 domainname offline

volume management will report the disk as offline / Needs Maintenance  


d14: Submirror of d4
  State: Needs maintenance Sun Jun 18 00:13:54 2017
  Invoke: metareplace d4 c1t1d0s4
  Size: 54940224 blocks (26 GB)
  Stripe 0:
Device Start Dbase State Reloc Hot Spare Time
c1t1d0s4 0 No Maintenance Yes Sun Jun 18 00:13:54 2017


/etc/path_to_inst
/pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000004cf6ba58e,0" 0 "ssd"

disks/ls-l_dev_rdsk.out

lrwxrwxrwx 1 root root 74 Sep 19 2008 c1t1d0s2 -> ../../devices/pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000004cf6ba58e,0:c,raw

/disks/iostat_-E.out

 ssd0     Soft Errors: 0 Hard Errors: 66 Transport Errors: 0

Vendor: SEAGATE  Product: ST373405FSUN72G  Revision: 0438 Serial No:            

Size: 0.00GB <0 bytes>

Media Error: 0 Device Not Ready: 66 No Device: 0 Recoverable: 0

Illegal Request: 0 Predictive Failure Analysis: 0


 

Solution

 
Replace c1t1d0 disk

540-5408 [F] 73.4GB - 10000 RPM FC-AL, Disk Assembly
 