![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2281806.1 : Device ssd0 failed to power up.
In this Document
Created from <SR 3-15145995071> Applies to:Sun Fire 280R Server - Version All Versions to All Versions [Release All Releases]Sun Fire V480 Server - Version All Versions to All Versions [Release All Releases] Sun Fire V490 Server - Version All Versions to All Versions [Release All Releases] Sun Fire V880 Server - Version All Versions to All Versions [Release All Releases] Sun Fire V890 Server - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsAVAILABLE DISK SELECTIONS: 0. c1t0d0 <SUN72G cyl 14087 alt 2 hd 24 sec 424> /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w2100000c509933e3,0 1. c1t1d0 <drive not available> /pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000004cf6ba58e,0 Changes
Causedevice failed to power up, these messages are seen in /var/adm/messages Jun 18 00:41:38 domainname genunix: [ID 405830 kern.warning] WARNING: Device ssd0 failed to power up. volume management will report the disk as offline / Needs Maintenance
disks/ls-l_dev_rdsk.out lrwxrwxrwx 1 root root 74 Sep 19 2008 c1t1d0s2 -> ../../devices/pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000004cf6ba58e,0:c,raw /disks/iostat_-E.out ssd0 Soft Errors: 0 Hard Errors: 66 Transport Errors: 0 Vendor: SEAGATE Product: ST373405FSUN72G Revision: 0438 Serial No: Size: 0.00GB <0 bytes> Media Error: 0 Device Not Ready: 66 No Device: 0 Recoverable: 0 Illegal Request: 0 Predictive Failure Analysis: 0
SolutionReplace c1t1d0 disk 540-5408 [F] 73.4GB - 10000 RPM FC-AL, Disk Assembly Attachments This solution has no attachment |
||||||||||||||||||
|