Problem Document
|
Synopsis
|
Last Modified Date
|
2382098.1 |
SPARC T8-1, T7-1: Faults on NVMe-SFF drives due to poorly seated cables |
2018-04-09
|
2370600.1 |
ILOM webgo corefiles + fault ILOM-8000-JV |
2018-04-20
|
2357844.1 |
T7-x: BoB DCAL command timeout errors reported against memory dimms. |
2018-02-06
|
2353961.1 |
T7-1 WARNING: nvmex 1 IO timeout (CSTS 1)! (CSTS 2) (CSTS 3) |
2018-01-27
|
2301011.1 |
ILOM Reboots due to Out of Memory or Hangs after ILOM 3.2.4 fixes |
2018-05-07
|
2262231.1 |
Solaris 11.3 - New LUN Mapped Not Visible in format - devfsadm failed to lookup dev name for |
2017-05-05
|
2254266.1 |
Java Applications Crash on T7/M7 SPARC Systems |
2017-11-07
|
2252368.1 |
Solaris reports incorrect Oracle Quad 10 Gb or Dual 40 Gb Ethernet Adapter card information on SPARC T7 |
2018-05-01
|
2245358.1 |
Solaris sun4v domains may panic after 1101 days of uptime |
2018-01-18
|
2211740.1 |
Failing to add a new host config to SP using ldm add-config command |
2018-05-01
|
2208651.1 |
Troubleshooting high fan speed in T-series systems |
2018-05-22
|
2189960.1 |
Firmware upgrade with existing faults from prior ILOM rev 3.2.6 to after results in misclassified Subsystem on T4-x, T5-x, & T7-x |
2018-01-12
|
2174444.1 |
Solaris 10 LDOM domain boots with the following events: "WARNING: Unsupported bootblk image, can not extract fcode", "WARNING: Bootblk fcode extraction failed" |
2018-05-01
|
2164409.1 |
SPARC: SMF-8000-YX: system/management/firmware-check:default is unavailable |
2017-10-05
|
2154454.1 |
T7 cannot boot from rcdrom |
2018-01-31
|
2149606.1 |
Solaris ipfilter settings can block traffic between Host and Service Processor causing "prtdiag -v" to lose environmental data and picld to report "PICL snmpplugin: cannot fetch object value" |
2018-05-10
|
2108433.1 |
Qlogic Script update_sol.sh Fails with the Message : Selected file has incorrect checksum (./FWA83xxB.DAT)! |
2018-02-08
|
2102941.1 |
SPARC S7/T7 rKVM Storage redirection fails to boot with sol-11_3-text-sparc.iso |
2018-01-02
|
2094452.1 |
SPARC T7-x : After firmware Update To SysFW 9.5.2.g or Later From Any SysFW Version Earlier Than 9.5.2.g Then ILOM FMA reports ILOM-8000-9W with fault class defect.ilom.fs.miniroot-missing |
2017-11-15
|
2076678.1 |
SPARC T7 and S7 Memory SEEPROM data does not contain a valid Oracle Part Number |
2017-11-15
|
1944663.1 |
T5xx0-T8 Servers: Service Processor Network connectivity lost without auto negotiation on Ethernet port |
2018-03-13
|
1643464.1 |
[SPARC T3/T4/T5 and T7] OBP reports "One or more resources have been retired, please run 'show faulty' on the SP" on console |
2017-10-05
|
1517032.1 |
T3-x, T4-x, T5-x, T7-x: Unrecognized Chassis: This Module Is Installed In An Unknown Or Unsupported Chassis. |
2018-03-05
|