Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2252368.1
Update Date:2018-05-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2252368.1 :   Solaris reports incorrect Oracle Quad 10 Gb or Dual 40 Gb Ethernet Adapter card information on SPARC T7  


Related Items
  • SPARC T7-2
  •  
  • SPARC T7-4
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T7
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-14442500401>

Applies to:

SPARC T7-1 - Version All Versions to All Versions [Release All Releases]
SPARC T7-2 - Version All Versions to All Versions [Release All Releases]
SPARC T7-4 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

SPARC T7-x systems support a single model of 7319817 ethernet card based on the Fortville B1 silicon. The B0 silicon based card is not support on SPARC T7 systems.

When flashed with FCode 3.3 (or earlier) Solaris will incorrectly report the cards as the B0 variant which is not supported on SPARC T7.

Fortville B1 card as reported by ILOM;

/System/PCI_Devices/Add-on/Device_1
Properties:
part_number = 7319817
description = Oracle Quad 10 Gb or Dual 40 Gb Ethernet Adapter
location = PCIE1 (PCIe Slot 1)
pci_vendor_id = 0x8086
pci_device_id = 0x1583
pci_subvendor_id = 0x108e
pci_subdevice_id = 0x7b1d

  

prtconf reports the same card as a B0 silicon version;

version: 'Oracle Quad 10Gb or Dual 40Gb Ethernet Adapter
FCode 3.3 12/23/2015'
board-model: '7096437'
model: '7111185/7111186'
compatible: 'pciex8086,1583.108e.7b1d.2' +
'pciex8086,1583.108e.7b1d' + 'pciex8086,1583.2' + 'pciex8086,1583' +
'pciexclass,020000' + 'pciexclass,0200'
address-bits: 00000030
max-frame-size: 00002400
network-interface-type: 'ethernet'
device_type: 'network'
name: 'network'
fcode-rom-offset: 00057a00
vf-stride: 00000001
first-vf-offset: 00000010
total-vfs: 00000020
initial-vfs: 00000020
#vfs: 00000020
port-type: 'PCIE-Endpoint'
interrupts: 00000001
cache-line-size: 00000010
class-code: 00020000
subsystem-id: 00007b1d
subsystem-vendor-id: 0000108e
revision-id: 00000002
device-id: 00001583
vendor-id: 00008086

  

Cause

Quad 10-Gigabit or Dual 40-Gigabit Ethernet QSFP+, part number 7319817, based on the Fortville B1 silicon require FCode 3.6.
 

Solution

Patch 23712513: ORACLE QUAD 10GB OR DUAL 40GB ETHERNET ADAPTER 5.2

References

<BUG:25694105> - FORTVILLE PN MISMATCH - ILOM REPORTS B1, OS REPORTS B0

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback