![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2252368.1 : Solaris reports incorrect Oracle Quad 10 Gb or Dual 40 Gb Ethernet Adapter card information on SPARC T7
In this Document
Created from <SR 3-14442500401> Applies to:SPARC T7-1 - Version All Versions to All Versions [Release All Releases]SPARC T7-2 - Version All Versions to All Versions [Release All Releases] SPARC T7-4 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsSPARC T7-x systems support a single model of 7319817 ethernet card based on the Fortville B1 silicon. The B0 silicon based card is not support on SPARC T7 systems. When flashed with FCode 3.3 (or earlier) Solaris will incorrectly report the cards as the B0 variant which is not supported on SPARC T7. Fortville B1 card as reported by ILOM; /System/PCI_Devices/Add-on/Device_1
Properties: part_number = 7319817 description = Oracle Quad 10 Gb or Dual 40 Gb Ethernet Adapter location = PCIE1 (PCIe Slot 1) pci_vendor_id = 0x8086 pci_device_id = 0x1583 pci_subvendor_id = 0x108e pci_subdevice_id = 0x7b1d
prtconf reports the same card as a B0 silicon version; version: 'Oracle Quad 10Gb or Dual 40Gb Ethernet Adapter
FCode 3.3 12/23/2015' board-model: '7096437' model: '7111185/7111186' compatible: 'pciex8086,1583.108e.7b1d.2' + 'pciex8086,1583.108e.7b1d' + 'pciex8086,1583.2' + 'pciex8086,1583' + 'pciexclass,020000' + 'pciexclass,0200' address-bits: 00000030 max-frame-size: 00002400 network-interface-type: 'ethernet' device_type: 'network' name: 'network' fcode-rom-offset: 00057a00 vf-stride: 00000001 first-vf-offset: 00000010 total-vfs: 00000020 initial-vfs: 00000020 #vfs: 00000020 port-type: 'PCIE-Endpoint' interrupts: 00000001 cache-line-size: 00000010 class-code: 00020000 subsystem-id: 00007b1d subsystem-vendor-id: 0000108e revision-id: 00000002 device-id: 00001583 vendor-id: 00008086
CauseQuad 10-Gigabit or Dual 40-Gigabit Ethernet QSFP+, part number 7319817, based on the Fortville B1 silicon require FCode 3.6. SolutionPatch 23712513: ORACLE QUAD 10GB OR DUAL 40GB ETHERNET ADAPTER 5.2 References<BUG:25694105> - FORTVILLE PN MISMATCH - ILOM REPORTS B1, OS REPORTS B0Attachments This solution has no attachment |
||||||||||||||||||
|