![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2108433.1 : Qlogic Script update_sol.sh Fails with the Message : Selected file has incorrect checksum (./FWA83xxB.DAT)!
In this Document
Created from <SR 3-12202903861> Applies to:SPARC T7-1 - Version All Versions and laterInformation in this document applies to any platform. SymptomsIn order to enable SR-IOV on Universal HBA you need to execute a One-Time firmware upgrade : This is documented on docs.oracle.com : Perform a One-Time Firmware Update For FC SR-IOV Support and in the Knowledge MOS Section in :
This is done by downloading and Update Kit from the Qlogic website and next executing the update_sol.sh script.
The update_sol.sh script may fail with the following error :
# update_sol.sh Flashing FW Preload Table... --- snipped ---
CauseThis is CR 22180621 : update_sol.sh script fails with incorrect checksum error for most QCCLI vers.
- Fixed preload table checksum.
On February 2016, 20 Qlogic was only providing the 6.0 version of the Multi-Boot Image Update Kit on its website SolutionAs long as Qlogic does not provide a fixed Multi-Boot Image Update Kit for this issue, please open a Service Request and ask for the fixed Update Kit which is attached to the CR 22180621
The following Update Kits are attached to CR 22180621 Oracle_QLE8362_SRIOV_Flash_Kit_06.2.zip Oracle_QEM8362_SRIOV_Flash_Kit_06.3.zip
References<BUG:22180621> - UPDATE_SOL.SH SCRIPT FAILS WITH INCORRECT CHECKSUM ERROR FOR MOST QCCLI VERS.<NOTE:1950167.1> - Unable To Create SR-IOV Virtual Instance For Qlogic 16 Gb Fibre Channel PCIe Universal Host Bus Adapter <NOTE:166650.1> - Working Effectively With Oracle Support - Best Practices Attachments This solution has no attachment |
||||||||||||||||||
|