How To
|
Canned Action Plan (CAP) Documents
|
Last Modified Date
|
2074066.1 |
How to Replace a Netra T2000 Memory DIMM [VCAP] |
2016-12-19
|
1488941.1 |
How to Replace a Netra T2000 System Board:ATR:1488941.1:0 |
2017-09-20
|
1488337.1 |
How to Replace a Netra T2000 Service Processor Battery:ATR:1488337.1:0 |
2017-11-02
|
1465193.1 |
How to Replace a Netra T2000 Alarm Board:ATR:1465193.1:0 |
2016-03-03
|
1465146.1 |
How to Replace a Netra T2000 PCI Card:ATR:1465146.1:0 |
2016-03-03
|
1464866.1 |
How to Replace a Netra T2000 Fan:ATR:1464866.1:0 |
2016-03-03
|
1464860.1 |
How to Replace a Netra T2000 Drive Cluster Assy:ATR:1464860.1:1 |
2017-09-20
|
1464847.1 |
How to Replace a Netra T2000 LED Board:ATR:1464847.1:1 |
2016-01-20
|
1464813.1 |
How to Replace a Netra T2000 Power Distribution Board:ATR:1464813.1:1 |
2016-01-20
|
1383820.1 |
How to Remove and Replace Netra T2000, Netra T5220, Netra T5440, Netra T3-1/T4-1, Netra CT4x0/8x0 System Components:ATR:1383820.1:2 |
2017-08-16
|
1361150.1 |
How to Perform On Site Diagnosis for a Down System for Sun Fire T1000/T2000, SPARC Enterprise T1000/T2000, Sun Blade T6300 and Netra T2000:ATR:1361150.1:2 |
2017-11-30
|
1308290.1 |
How to Replace a Sun Fire or Netra T2000 Service Processor (ALOM) [VCAP] |
2017-08-14
|
1308281.1 |
How to Replace a Sun Fire and Netra T2000 DVD:ATR:1602:1 |
2017-12-01
|
1308261.1 |
How to Replace a Sun Enterprise/Fire or Netra T2000 Power Supply:ATR:1183:0 [VIDEO] |
2017-08-04
|
1307783.1 |
How to Replace a Sun Fire or Netra T2000 Hard Disk Drive:ATR:1169:0 |
2017-10-10
|
1019720.1 |
How to Replace the Motherboard or Service Processor in a Logical Domain (LDom) Environment |
2018-02-08
|
How To
|
Non CAP Knowledge Documents
|
Last Modified Date
|
1452873.1 |
How to Recognize and Diagnose Service Processor Battery Failure on Sun Fire/Netra T1000/T2000 & Sun Blade T6300/T6320/T6340 |
2017-05-22
|
1342226.1 |
How to Download Firmware for Oracle Systems and Storage |
2017-10-18
|
1020016.1 |
Verify link configuration and vnet settings in LDOM |
2017-10-02
|
1019984.1 |
Steps to confirm the right cpu archictecture is specified when Jumpstarting Txxxx (sun4v) server. |
2014-09-22
|
1019594.1 |
ALOM network port unresponsive after network switch power cycle |
2017-11-30
|
1012949.1 |
How to Determine the System Firmware Version on T1000/T2000 |
2018-01-05
|
1012645.1 |
How to Collect ALOM Data from the OS on T1000/T2000 Servers |
2017-10-05
|
1012360.1 |
How to determine which systems have ILOM/ALOM4v/ALOM/LOM/ELOM/SP/XSCF or RSC ? |
2018-03-01
|
1011226.1 |
Selecting the firmware upgrade method on T1000/T2000 |
2017-10-11
|
1005907.1 |
SPARC Platforms: Matrix of Recognized Device Paths |
2018-02-28
|
1004229.1 |
How To Clear FMA faults from Solaris[TM] and SC (System Controller) on T1000/T2000 T5120/T5220/T5140/T5240/T5440,T6320,T6340, T3-1/T3-2/T3-4, T4-1/T4-2/T4-4 |
2018-03-14
|
1003456.1 |
STMS (MPxIO) degraded path messages seen at Solaris[TM] 8, 9, 10, or 11 boot time. |
2017-11-30
|
1003034.1 |
Flash PROM patches / Minimum Supported Operating Environment Versions for Sun systems |
2016-11-29
|