Solution Type  Technical Instruction Sure

Solution  1464847.1 :   How to Replace a Netra T2000 LED Board:ATR:1464847.1:1  


Related Items
  • Sun Netra T2000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Oracle Confidential (INTERNAL). Do not distribute to customers.
Reason: FRU CAP

Applies to:

Sun Netra T2000 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Netra T2000 LED Board

********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1464847.1
********************************************************************************

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
FE hardware skills, familiarity or training for T2000 platform.

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 1

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW: Replacement of LED board

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Customer should shut the operating system down gracefully (using "init 5"), and after the system has shut down run the following commands from the ALOM:

1. setlocator on
2. poweroff

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Remove the LED board:

1. Verify the system has been shut down by the customer.

2. Remove top cover

3. Remove PCI Tray

4. Remove DIMM/CPU air duct

5. Remove the fan assy.

6. Loosen the thumbscrew of the LED board and swing the board out to the left.

7. Carefully lift the LED board and cable from the cable clips.

8. Disconnect the cable from the LED board


Install new LED board:

1. Connect the cable to the LED board.

2. Insert the tab on the LED board into the slot on the chassis

3. Swing the LED board right to the chassis and tighten the thumbscrew.

4. Route the LED board cable back into the cable guides.

5. Install the fan assembly.

6. Install the DIMM/CPU duct.

7. Install PCI Tray

8. Replace the top cover.


OBTAIN CUSTOMER ACCEPTANCE:
Visually inspect the new LED/Switch board.

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: N/A

PARTS NOTE:   https://support.oracle.com/handbook_private/Systems/Netra_T2000/components.html#exploded_view

REFERENCE INFORMATION:   http://docs.oracle.com/cd/E19596-01/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback