Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge 6020/6120 Array : How To


The How To documents are presented with two different sections. Select the section of interest below.

Canned Action Plan (CAP) Documents

Non CAP Knowledge Documents


How To Canned Action Plan (CAP) Documents Last Modified Date
1620937.1 How to Remove and Replace a 6020/6120 HDD 2016-01-20
1316247.1 How to Remove and Replace a SE6X20 and T3 Power Cooling Unit:ATR:1730:2 [Video] 2017-07-28
1316241.1 How to Remove and Replace a Sun StorEdge 6020/6120 Array Battery [VCAP] 2017-08-23
1316211.1 How to Remove and Replace a SE6X20 and T3 Ethernet Cable:ATR:1728:1 2017-03-22
1316210.1 How to Remove and Replace a SE6X20 and T3 Interconnect Cable:ATR:1727:2 2017-03-21
1315708.1 How to Remove and Replace a SE6X20 and T3 Power Cord Kit:ATR:1725:0 2017-03-22
1315687.1 How to Remove and Replace a SE6X20 and T3 Chassis Midplane:ATR:1724:4 2017-03-22
1315627.1 How to Remove and Replace a SE6X20 and T3 Array Interconnect Card:ATR:1723:2 2017-03-21
1314252.1 How to Remove and Replace a SE6X20 and T3 RAID Controller:ATR:1722:3 2017-03-22
1002135.1 How to replace the Power Cooling Unit in a StorEdge[TM] 6120 array ? 2015-11-12
How To Non CAP Knowledge Documents Last Modified Date
1395568.1 ASR & How to Collect Common Array Logs For Advance Troubleshooting Of ASR (Auto Service Request) Issues 2016-06-03
1018649.1 Sun StorEdge[TM] 6120: How to register a SE6120 into Configuration Service 2014-03-11
1012557.1 Sun StorEdge[TM] 3510/3511 Arrays: Understanding Link Error Status Block (LESB) counters. 2016-10-12
1011735.1 How to Add New Storage Disk Devices to Solaris[TM] Without Performing a Reconfiguration Boot 2017-06-04
1010350.1 Sun StorEdge[TM] T3: Technical Instruction: T3+ - Solaris and Recognition of Larger-than-1TB volume. 2014-03-11
1007590.1 Sun StorEdge[TM] T3, T3+, and 6x20 Arrays: Some Precautions For Upgrading 2014-03-11
1004983.1 Creating a data pool without a hotspare using the factory default configuration of the Sun StorEdge[TM] 6020/Sun StorEdge[TM] 6120 2014-03-11
1003719.1 How to Identify a Sun StorEdge 6320 LUN Within the Format Utility on a Solaris Host 2015-09-03
1003516.1 Meaning of LT_OP and LT_TASK Messages in Sun StorEdge[TM] T3+/SE6x20 syslog 2016-08-01
1002199.1 problems with ftp to Sun StorEdge[TM] T3/6120 after fw upgrade 2014-03-11
1001917.1 Collecting crash dumps from Sun StorEdge[TM] T3+/6020/6120 arrays 2017-05-02
1001781.1 Sun StorEdge[TM] A5x00, T3, 6120, 33xx, 351xFC, A3500FC Arrays: Disk Firmware/Patch Matrix Summary 2016-12-28
  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
 Feedback