![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1315687.1 : How to Remove and Replace a SE6X20 and T3 Chassis Midplane:ATR:1724:4
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers
Applies to:Sun Storage 6320 System - Version: Not Applicable and later [Release: N/A and later ]Sun Storage T3+ Array - Version: Not Applicable and later [Release: N/A and later] Sun Storage 6020 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage 6120 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage T3 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Information in this document applies to any platform. GoalSE6X20 and T3 Chassis MidplaneSolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) T3 / 6x20 product training TASK COMPLEXITY: 4 TIME ESTIMATE: 180 minutes FIELD ENGINEER INSTRUCTIONS PROBLEM OVERVIEW: Replace centerplane and chassis on storage array. WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : Full verified backups of all data and operating systems potentially affected by service activities. This is a cold swap component and will require system down time. The array needs to be shut down and powered off for the duration of the service activity. POWER OFF RAID TRAYS FIRST. It may be optional to leave the host(s) booted, but it is up to the customer to ensure that all dependencies of the array to be serviced have been removed. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: Follow standard ESD precautions. Follow procedures documented in the respective service documentation listed below. Note that the documentation for the SE6x20 product includes cases for standalone SE6120 enclosures and how to handle an array chassis mounted in a Maserati rack. The customer may have to re-register a standalone array with their management software. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: 1. Power on Array Expansions 2. Power on RAID Controller Trays(no particular order) 3. After 10 minutes, verify fru status(all parts should be ready enabled) 4. Verify volume status(vol stat - should show all volumes mounted) 5. Host Access should now be allowed. PARTS NOTE: REFERENCE INFORMATION: T3 and T3+ Array Installation, Operation and Service Manual: http://download.oracle.com/docs/cd/E19699-01/ Storedge 6x20 System 1.2 Reference and Service Guide: http://download.oracle.com/docs/cd/E19957-01/ Attachments This solution has no attachment |
||||||||||||
|