Problem Document
|
Synopsis
|
Last Modified Date
|
2116281.1 |
Oracle ZFS Storage Appliance: Connecting Internal SAS Cable to the Backplane Port |
2018-01-05
|
2099111.1 |
MegaCli command return "No match" |
2017-07-07
|
2076251.1 |
x86 Platforms: 300GB, 600GB, 900GB and 1.2TB Disk Firmware Upgrade to Address Unrecoverable Read Errors |
2016-04-18
|
2049270.1 |
Solaris 10 Fails To Replace a SCSI Disk under SVM - Application(s) accessing previously attached SATA device have to release it before newly inserted device can be made accessible. |
2016-08-01
|
1998581.1 |
The Solaris message "unsupported 64-bit Prefetch Memory On Pci-pci Bridge" might appear on boot on X4170 or X4270 M2 |
2018-03-22
|
1919457.1 |
"Energy Storage Module Is Approaching or has Reached End-of-life" ILOM error message. |
2017-08-02
|
1671764.1 |
Replacement disk managed by LSI not recognised by OS |
2018-02-26
|
1645310.1 |
Red Hat Linux - FC HBA Qla2xxx Abort Command Issued, qla2xxx_eh_bus_reset: reset succeeded To Sun ZFS Storage 7320 Through Brocade 300 |
2017-02-13
|
1612084.1 |
X3-2 : ILOM does not respond if the ethernet cable is connected after power on. |
2014-05-30
|
1610229.1 |
X86 Systems : usba "Connecting device on port 3 failed" WARNING message reports at Solaris boot. |
2016-08-26
|
1606837.1 |
Disk reported unexpected SCSI SENSE data to controller which may indicate a compatibility issue between the controller firmware version and disk model, sun-id=/SYS/DBP/HDDx |
2018-03-26
|
1576683.1 |
Windows BSOD WHEA_UNCORRECTABLE_ERROR(124) & correctable WHEA events when disabling network ports on X4170M2/X4270M2 |
2014-04-02
|
1560060.1 |
When Upgrading ILOM/BIOS FW on X4270 M2 Server from SW 1.3 to SW 1.6/1.7 the System becomes Non-bootable, Resetting Itself Iindefinitely |
2018-03-22
|
1557029.1 |
Memory Reference Code Not Cleared for AP's Resulting in False SPX86-8001-ME Population Errors |
2016-11-16
|
1557001.1 |
Memory Reference Code Not Cleared for Auxiliary Processors Resulting in False SPX86-8001-U5 UE Error |
2016-11-16
|
1523297.1 |
SP (ILOM) enters "ILOM Pre-boot Menu" (Preboot>) after "reset /SP"; Boots fine from a cold start (unplug/plugin power cords) |
2017-10-05
|
1519636.1 |
"Deferred Adapter Hardware Error Data:..." error on Oracle Emulex FC HBA card with old 1.00A12 firmware on Oracle Linux server |
2013-01-30
|
1495513.1 |
X4270M2 Storage Cell Fails to Boot and is Seen as X4170M2 on Exadata Platform |
2018-04-09
|
1490545.1 |
SM BIOS Uncorrectable CPU-complex Error in ILOM SEL and system hard hangs when running sosreport or commands such as lspci |
2016-07-18
|
1359338.1 |
Sun Fire X4270/X4275 May Panic with "pcieb-4: PCI(-X) Express Fatal Error. (0x101)" |
2018-04-02
|
1325578.1 |
Sun x64 Servers: How to change Solaris O/S console login to output through ILOM's start /SP/console |
2013-02-05
|
1304922.1 |
SB replacement can lead to to a serial number of '00000000' on certain Sun x86 Intel based Servers |
2016-11-16
|