![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1610229.1 : X86 Systems : usba "Connecting device on port 3 failed" WARNING message reports at Solaris boot.
In this Document
Created from <SR 3-8158062601> Applies to:Sun Server X2-4 - Version All Versions and laterSun Server X3-2L - Version All Versions and later Sun Server X3-2 - Version All Versions and later Sun Fire X4270 M2 Server - Version All Versions and later Sun Fire X4170 M2 Server - Version All Versions and later Information in this document applies to any platform. SymptomsTo discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems
X86 system reports the following warning during Solaris 10 boot after the cold boot or resetting SP:
SunOS Release 5.10 Version Generic_147148-26 64-bit
Copyright (c) 1983, 2013, Oracle and/or its affiliates. All rights reserved. Hostname: x4470m2 x4470m2 console login: Dec 24 11:28:53 x4470m2 usba: WARNING: /pci@0,0/pci108e,4848@1a,7/hub@3 (hubd1): Connecting device on port 3 failed
CauseThe warning appears because the ilomconfig-interconnect start has the "Internal error" as follows: bash-3.2# tail /var/svc/log/network-ilomconfig-interconnect:default.log
Host-to-ILOM interconnect disabled. [ Dec 24 11:21:25 Method "stop" exited with status 0 ] [ Dec 24 11:28:32 Executing start method ("/lib/svc/method/svc-ilomconfig-interconnect start") ] ERROR: Internal error Set host ipaddress to 'xxx.xxx.xxx.xxx' Host-to-ILOM interconnect successfully configured. [ Dec 24 11:30:13 Method "start" exited with status 0 ] bash-3.2# Since the ilomconfig-interconnect has started subsequently, this warning can be ignored. SolutionInstall patch 149639-04 for Solaris 10 x86. A workaround is provided by a <Bug: 15778364> References<NOTE:1583230.1> - SPARC T3/T4: usba:(hubd2): "Connecting device on port 3 failed" WARNING message reported at system boot<BUG:15778364> - SUNBT7153026 ILOMCONFIG-INTERCONNECT ERRORS IN SMF LOG ON BOOTED TE Attachments This solution has no attachment |
||||||||||||||||||
|