Problem Document Synopsis Last Modified Date
2335574.1 Exadata Compute Node Re-Image Stuck In Network Configuration Loop 2018-04-23
2329763.1 Engineered Systems - IB Switch Upgrade via patchmgr Fails With "[FAIL] Error(s) encountered during execution" 2018-04-23
2301392.1 Unable To Launch ILOM Remote System Console Plus With Java 7 2017-08-29
2284109.1 "ASR: HALRT-02024: Cache Vault degradation." logged by one or more Exadata X6 Compute (DB) nodes after Disk Expansion Kits are installed. 2017-08-06
2280595.1 During upgrading or re-booting of an Infiniband switch from version 2.1.x the switch will not boot, NO Link Lights, Fans spinning full speed 2017-09-12
2279622.1 exachk IPv6 localhost ping test fails when it shouldn't 2017-08-24
2276427.1 Infiniband - Port HCA-#:# Is Showing Non-Zero Error Counts 2017-06-19
2273254.1 "Undo metadata area is bad" Error During Patchmgr Bug Exposure Check 2017-07-10
2272177.1 Understanding MRdiagd Events in /var/log/messages file Produced by Internal RAID HBA 2018-04-09
2256678.1 Exachk fails on Eth5 Down 2017-05-08
2249406.1 ibqueryerrors Reports PortXmitWait errors on One or More of the IB switch or HCA port 2018-04-23
2248506.1 Sun Rack II - PDU Monitoring units hang/become unresponsive during Network Security Scans and/or Other types of network activity. 2017-03-31
2241139.1 Kernel Crashes Cause an X6-2 System to Reboot Repeatedly. 2017-12-10
2233866.1 Unable to use the Virtual CDROM on ILOM Remote System Console Plus 2018-04-12
2216951.1 PCIE-Fatal Errors Reported in ILOM when NVMe Drives are Incorrectly Removed from Server 2017-09-18
2194997.1 Creating Second Database Using OEDA Fails with "OCMD-02624: Error While Executing Command {0}.java.lang.reflect.InvocationTargetException" 2016-10-26
2192650.1 Exadata Command "drop for replacement" Fails With CELL-02018 2017-11-15
2177634.1 When Attempting to Change the Number of Cores, Errors With: DBM-10004 - Decreasing the Number of Active Cores is not Supported 2018-01-08
2176276.1 Exadata X5/X6 reports "Disk controller was hung. Cell was power cycled to stop the hang." on SW images prior to 12.1.2.3.3.161109 2017-06-13
2099390.1 Exadata Storage Cells and DB Nodes reset ILOM periodically 2017-07-17
1502699.1 Oracle Linux syslog reports 'RDS: rds_bind() could not find a transport, load rds_tcp or rds_rdma?' 2018-04-20