![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 2099390.1 : Exadata Storage Cells and DB Nodes reset ILOM periodically
Applies to:Exadata X4-2 Hardware - Version All Versions to All Versions [Release All Releases]Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases] Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases] Exadata X5-2 Hardware - Version All Versions to All Versions [Release All Releases] Exadata X6-2 Hardware - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsA user may notice that the ILOM of an Exadata's Storage Cells and DB Nodes will be reset occasionally. When this happens the following entry in the system event list may be seen- 89 Thu Jul 9 20:33:25 2015 Power Reset major
/SP has been reset by: IPMI, Reason: Set PSU state When the ILOM is reset you will notice that the network switch connected to the network management port will report a "Link Down" for the port while the reset is in progress. Also of note is that the OS will log the disconnecting of the ILOM's virtual usb devices CD-ROM/floppy/etc. CauseStarting with Exadata release 11.2.3.3.0 each server has it's own periodic reset time which will perform a reset of the ILOM every 90 days. In addition to these scheduled resets the MS process can also reset ILOM prior to the periodic target reset time if it times out when accessing the ILOM. When this reset is initiated by the Exadata software the following entry will be seen in the ms-odl.log file [2014-05-11T17:58:51.006+09:00] [ossmgmt] [NOTIFICATION] [] [common.hwadapter.bmcadp.BmcIpmiTool] [tid: 38] [ecid: 10.9.3.72:75793:1399798731006:174860,0] Periodic reset interval is up. The ILOM will now be reset.
This change is documented in the what's new section of the Exadata overview document: http://docs.oracle.com/cd/E50790_01/doc/doc.121/e51953/app_whatsnew.htm#BGGDGCIE SolutionThis behavior is normal and expected. The Exadata system is configured so that a Server's ILOM is reset every 90 days. References<NOTE:1679737.1> - One or More Storage Server ILOMs Report as Being ResetAttachments This solution has no attachment |
||||||||||||
|