Alert
|
Synopsis
|
Last Modified Date
|
2380939.1 |
SPARC M5, M6, and M7 Servers Physical Domain(s) may Unexpectedly Reset Following the Reset of the Active Service Processor |
2018-03-30
|
2345930.1 |
SPARC Solaris sun4v Domains With Certain Firmware may Panic After 1101 Days of Uptime |
2018-01-17
|
2344587.1 |
SERVICE ALERT WEEKLY SUMMARY REPORT (2017) |
2018-01-02
|
2340021.1 |
SPARC M5-32 and M6-32 Servers With Firmware Versions Prior to 9.6.20.b May Erroneously Fault a CMU board for Memory Link Failover |
2017-12-15
|
2300665.1 |
SPARC M5-32, M6-32, M7-8, M7-16, M8-8 Systems With Certain Firmware Versions may Fail to Boot when Device Identification is Unreadable |
2018-01-23
|
2219596.1 |
SERVICE ALERT WEEKLY SUMMARY REPORT (2016) |
2017-01-03
|
2188787.1 |
SPARC M5-32 and M6-32 Systems With System Firmware Versions 9.5.3 through 9.6.5.a May Experience Solaris Panic Due to Certain PCIe Fabric Errors |
2017-07-25
|
2179881.1 |
SPARC T4, T5/M5/M6 or T7/S7/M7 Platforms Configured Explicitly for Cross-CPU Migration may Experience Memory Corruption in Oracle VM Server for SPARC Guest Domains and Solaris Kernel Zones |
2017-01-18
|
2169382.1 |
For SPARC T4, T5 Series and SPARC M5-32/M6-32 Servers, System Firmware Version 8.9.5 and 9.6.5 May Cause System Panic (Firmware 8.9.5 and 9.6.5 are WITHDRAWN) |
2017-11-27
|
2133737.1 |
SPARC M5-32 and M6-32 Servers With Sun System Firmware 9.4.2.d, 9.4.2.e, 9.5.1.c, or 9.5.3 may Misidentify Faulty Components or Fail to Diagnose Faulty Components |
2016-05-16
|
2130478.1 |
SPARC M5-32/M6-32 Systems With Sun System Firmware 9.5.3 or Earlier may Crash Unexpectedly While Running |
2017-11-28
|
2044894.1 |
Infiniband Switch Reboot May Cause Database Crash or Node Eviction on SuperCluster |
2017-06-26
|
2034535.1 |
SPARC M5-32/M6-32 Servers Physical Domain (PDom) may Become Unresponsive After Upgrading to Sun System Firmware 9.3.0.f |
2015-07-21
|
2027245.1 |
SPARC T5 Series and SPARC M5-32/M6-32 Servers System Firmware Version 9.4.2.c and 9.4.2.d May Erroneously Disable CPUs |
2017-01-03
|
2002410.1 |
Oracle ILOM FIPS Mode May Fail on SPARC M5-32/M6-32 Servers With Sun System Firmware 9.3.0.c or Later |
2015-12-18
|
2001254.1 |
Oracle Enterprise Ops Center 12c Release 2 Monitoring Will be Impaired for SPARC M5-32 & M6-32 Servers With Sun System Firmware 9.3.0.c and Later Releases |
2017-04-24
|
1968958.1 |
Sun System Firmware 8.6.0.b, 8.6.0.c, and 9.3.0.b through 9.3.0.f May Cause Guest Domains to be Unresponsive Following a Live Migration |
2016-12-07
|
1966721.1 |
SPARC M5-32 and M6-32 Servers running Sun System Firmware 9.3.0.c may Erroneously Mark Multiple CPU/Memory Units (CMUs) as Faulty When Starting Physical Domains |
2015-02-02
|
1946535.1 |
Oracle Virtual Machine (OVM) Server for SPARC Guest Domains may not Accept Console Input on SPARC T4/T5/M5/M6 Series Servers Running Sun System Firmware Releases 8.5.1.b and 9.2.1.B/C |
2016-06-02
|
1675249.1 |
Collecting a Full Snapshot (dataset=full) on SPARC M5-32 or M6-32 Servers Running Sun System Firmware 9.2.0.b will Trigger Unplanned HOSTs Poweroff |
2016-06-13
|
1664921.1 |
Issue With SPARC M5/M6-32 PSUs Requires Firmware Upgrade |
2014-05-27
|
1632919.1 |
SPARC M5-32 and M6-32 Servers may Require Sun System Firmware Revision 9.1.1.b or Later When Replacing Fan Modules |
2014-03-06
|
1616929.1 |
Firmware 9.0.1_ on SPARC M6-32 and SPARC M5-32 (with M6 CMUs) Servers May Lead to a System Panic |
2014-02-06
|
1021776.1 |
SERVICE ALERT WEEKLY SUMMARY REPORT (2018) |
2018-05-29
|