Solution Type  Sun Alert Sure

Solution  1946535.1 :   Oracle Virtual Machine (OVM) Server for SPARC Guest Domains may not Accept Console Input on SPARC T4/T5/M5/M6 Series Servers Running Sun System Firmware Releases 8.5.1.b and 9.2.1.B/C  


Related Items
  • SPARC M5-32
  •  
  • Netra SPARC T4-1 Server
  •  
  • SPARC T5-1B
  •  
  • SPARC T4-2
  •  
  • Sun Software - Generic
  •  
  • Netra SPARC T3-1B
  •  
  • SPARC T4-1
  •  
  • SPARC T4-1B
  •  
  • SPARC T5-2
  •  
  • SPARC M6-32
  •  
  • Netra SPARC T4-2 Server
  •  
  • SPARC T5-4
  •  
  • SPARC T4-4
  •  
  • Netra SPARC T4-1B
  •  
  • SPARC T5-8
  •  
  • Sun Hardware - Generic
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun Alert
  •  
  • _Old GCS Categories>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • _Old GCS Categories>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  




In this Document
Description
Occurrence
Symptoms
Workaround
 Resolution:

This issue is addressed in the following releases:
Patches
History
References


Applies to:

SPARC M6-32
SPARC M5-32
Netra SPARC T3-1B
SPARC T4-1
SPARC T4-1B
SPARC
__________________________________________
Additional affected platforms:

Netra SPARC T4-2
SPARC T5-1B
SPARC T5-2
SPARC T5-4
SPARC T5-8
Netra SPARC T5-1B
SPARC M5-32
SPARC M6-32



Date of Workaround Release: 19-Nov-2014

Date of Resolved Release:25-Nov-2014
__________________________________________

Description

Oracle Virtual Machine (OVM) Server for SPARC Guest Domains on SPARC T4/T5/M5/M6 series servers running Sun System Firmware releases 8.5.1.b and 9.2.1.B/C may not accept console input and may appear hung after running the command 'ldm unbind <ldom>'.

Note: Input at the Open Boot PROM (OBP) will still function normally.

Occurrence

This issue can occur on the following platforms:

SPARC Platform:

  • SPARC T4-1 with Sun System Firmware 8.5.1.b (as delivered in patch 151295-02)
  • SPARC T4-2 with Sun System Firmware 8.5.1.b (as delivered in patch 151296-02)
  • SPARC T4-4 with Sun System Firmware 8.5.1.b (as delivered in patch 151297-02)
  • SPARC T4-1B with Sun System Firmware 8.5.1.b (as delivered in patch 151298-02)
  • Netra SPARC T4-1 with Sun System Firmware 8.5.1.b (as delivered in patch 151299-02)
  • Netra SPARC T4-2 with Sun System Firmware 8.5.1.b (as delivered in patch 151300-02)
  • Netra SPARC T4-1B with Sun System Firmware 8.5.1.b (as delivered in patch 151301-02)
  • SPARC T5-2 with Sun System Firmware 9.2.1.B (as delivered in patch Patch 19264421)
  • SPARC T5-4+T5-8 with Sun System Firmware 9.2.1.B  (as delivered in patch 19264423)
  • SPARC T5-1B with Sun System Firmware 9.2.1.B (as delivered in patch 19264419)
  • Netra SPARC T5-1B with Sun System Firmware 9.2.1.B (as delivered in patch 19264425)
  • SPARC M5-32+M6-32 with Sun System Firmware 9.2.1.B (as delivered in patch 19264417)
  • SPARC M5-32+M6-32 with Sun System Firmware 9.2.1.C (as delivered in patch 19525299)

Note: This issue has been observed after running the 'ldm unbind <ldom>' command which releases resources bound to a configured guest domain.

To determine the firmware version on the system, the following command can be used:

    # prtdiag -v | grep Firmware
    Sun System Firmware 8.2.0.a 2012/05/11 07:34

Symptoms

If the described issue occurs, the console connection (ie 'telnet localhost 5000') to the guest domain will not accept any input, and may appear hung, although any console output will still be displayed normally.  This will only happen if the guest domain has had an unbind operation since the last host power cycle.  Input at the OBP prompt will still function normally.

Example:

    root@primary:~# telnet localhost 5000

    Trying 127.0.0.1...
    Connected to localhost.
    Escape character is '^]'.

    Connecting to console "primary" in group "primary" ....
    Press ~? for control options ..
    <<< no input accepted >>>

Workaround

If this issue has occurred, it is necessary to power cycle the system to regain control of the guest domain console.

Resolution:

This issue is addressed in the following releases:

SPARC Platform:

  • SPARC T4-1 with Sun System Firmware 8.6.0.b (as delivered in patch 151682-01) or later
  • SPARC T4-2 with Sun System Firmware 8.6.0.b (as delivered in patch 151683-01) or later
  • SPARC T4-4 with Sun System Firmware 8.6.0.b (as delivered in patch 151684-01) or later
  • SPARC T4-1B with Sun System Firmware 8.6.0.b (as delivered in patch 151685-01) or later
  • Netra SPARC T4-1 with Sun System Firmware 8.6.0.b (as delivered in patch 151686-01) or later
  • Netra SPARC T4-2 with Sun System Firmware 8.6.0.b (as delivered in patch 151687-01) or later
  • Netra SPARC T4-1B with Sun System Firmware 8.6.0.b (as delivered in patch 151688-01) or later
  • SPARC T5-2 with Sun System Firmware 9.3.0.B (as delivered in patch Patch 20034526) or later
  • SPARC T5-4+T5-8 with Sun System Firmware 9.3.0.B  (as delivered in patch 20034528) or later
  • SPARC T5-1B with Sun System Firmware 9.3.0.B (as delivered in patch 20034530) or later
  • Netra SPARC T5-1B with Sun System Firmware 9.3.0.B (as delivered in patch 20034531) or later
  • SPARC M5-32+M6-32 with Sun System Firmware 9.3.0.C (as delivered in patch 20034532) or later


Patches

<SUNPATCH:151682-01>
<SUNPATCH:151683-01>
<SUNPATCH:151684-01>
<SUNPATCH:151685-01>
<SUNPATCH:151686-01>
<SUNPATCH:151687-01>
<SUNPATCH:151688-01>
<SUNPATCH:20034526>
<SUNPATCH:20034528>
<SUNPATCH:20034530>
<SUNPATCH:20034531>
<SUNPATCH:20034532>

 

History

19-Nov-2014: Document released, status Workaround
25-Nov-2014: Updated Workaround section. Status Resolved

Internal Section: Comments:

This regression was introduced by putback for BugID: 17923956.

Questions regarding this document should be addressed to
sunalertpublication_us_grp@oracle.com and copy the
submitter/responsible engineer listed below.

Internal Contributor/Submitter: Grant.Gredvig@oracle.com
Internal Eng Responsible Engineer: Grant.Gredvig@oracle.com
Oracle Knowledge Analyst: jeff.folla@oracle.com
Internal Eng Business Unit Group: Systems RPE
Internal Associated SRs:
Internal Pending Patches:
Internal Resolution Patches: 9.3.0.x 8.5.2.x