![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Sun Alert Sure Solution 2219596.1 : SERVICE ALERT WEEKLY SUMMARY REPORT (2016)
Applies to:Netra SPARC T4-1BSun Blade T6340 Server Module SPARC S7-2 Sun Server X4-8 Pillar Axiom 500 Storage System Information in this document applies to any platform. DescriptionService Alerts that have been updated for currency check or internal maintenance issues with no significant change in content are not reflected in this report.
The SERVICE ALERT WEEKLY SUMMARY REPORT (2015) can be found in <Document:2093796.1> The SERVICE ALERT WEEKLY SUMMARY REPORT (2014) can be found in <Document:1958236.1> The Sun Alert Weekly Summary Report for 2013 can be found in <Document:1611635.1> The Sun Alert Weekly Summary Report for 2012 can be found in <Document:1517133.1> The Sun Alert Weekly Summary Report for 2011 can be found in <Document:1392057.1> The Sun Alert Weekly Summary Report for 2010 can be found in <Document:1279973.1> Oracle Security Alerts and related issues are now reported on the "Critical Patch Update (CPU) and Security Alerts" page, which can be found at: https://www.oracle.com/technetwork/topics/security/alerts-086861.html 25-Dec-2016 to 31-Dec-2016: No new or updated Service Alerts were released for the final week of 2016 (U.S. Holiday). For the SERVICE ALERT WEEKLY SUMMARY REPORT (2017), see <Document:1021776.1>
18-Dec-2016 to 24-Dec-2016: New: Service Alert <Document:2217511.1> - ZFS Storage Appliance (ZFSSA) Software May Erroneously Report that Clustron PCIe Cards are Faulty Updated: Service Alert <Document:2179881.1> - SPARC T4, T5/M5/M6 or T7/S7/M7 Platforms Configured Explicitly for Cross-CPU Migration may Experience Memory Service Alert <Document:2192534.1> - On Solaris 11.3.1.5.0 or Later, Use of ZFS ARC may Cause System Panics and Performance Issues Leading to Hangs
11-Dec-2016 to 17-Dec-2016: New: Service Alert <Document:2213222.1> - Solaris 11 may Experience RAC Node Evictions Due to Slowness in Kernel Memory Allocations Service Alert <Document:2213203.1> - Oracle Solaris Cluster and Oracle VM Server for SPARC Logical Domain Resources Using Live Migration to Perform a Rolling Upgrade to Oracle Solaris Cluster 4.3.4.4.0 will Trigger a Cold Migration of the Oracle VM Server for SPARC Logical Domain Resources Service Alert <Document:2214369.1> - ZFS Storage Appliance (ZFSSA) Software and Solaris 11 IP over Infiniband Data Links (IPoIB), may Stall When High RMAN (Oracle Recovery Manager) Backup Loads are Run From Linux 2.6 Based Client Nodes Updated: Service Alert <Document:2109480.1> - Solaris 11 Systems may Experience UFS File System Data Integrity Issues Which may Fail to be Reported Service Alert <Document:2209749.1> - A 'Replication Action' for the ZFS Storage Appliance (ZFSSA) Software may Stop Sending Data
04-Dec-2016 to 10-Dec-2016: Updated: Service Alert <Document:2102284.1> - eeprom Related Commands may Hang or Fail on SuperCluster Version 2.0 and 2.1 Systems
27-Nov-2016 to 03-Dec-2016: New: Service Alert <Document:2209749.1> - A 'Replication Action' for the ZFS Storage Appliance (ZFSSA) Software may Stop Sending Data Updated: Service Alert <Document:2179881.1> - SPARC T4, T5/M5/M6 or T7/S7/M7 Platforms Configured Explicitly for Cross-CPU Migration may Experience Memory Corruption in Oracle VM Server for SPARC Guest Domains and Solaris Kernel Zones
20-Nov-2016 to 26-Nov-2016: Updated: Service Alert <Document:2201386.1> - Solaris 11.3.13.4.0 may Erroneously Experience I/O Failure When All Active/Optimized Paths Become Offline Service Alert <Document:2179881.1> - SPARC T4, T5/M5/M6 or T7/S7/M7 Platforms Configured Explicitly for Cross-CPU Migration may Experience Memory Corruption in Oracle VM Server for SPARC Guest Domains and Solaris Kernel Zones
13-Nov-2016 to 19-Nov-2016: No new or updated Service Alerts were released during this time period.
06-Nov-2016 to 12-Nov-2016: New: Service Alert <Document:2201386.1> - Solaris 11.3.13.4.0 may Erroneously Experience I/O Failure When All Active/Optimized Paths Become Offline Service Alert <Document:2202266.1> - ZFS Storage Appliance (ZFSSA) Software 2013.1.6.0 through 2013.1.6.6 may Panic in rfs4_return_deleg() if Using NFSv4 with Delegation Enabled Updated: Service Alert <Document:2194147.1> - Solaris syslogd(1M) with Certain Patches Installed may Report a Harmless I/O Error During System or Zone Shutdown
30-Oct-2016 to 05-Nov-2016: Updated: Service Alert <Document:2179100.1> - Solaris 11 (x86) and ZFS Storage Appliance (ZFSSA) Software may Experience a BAD TRAP Panic on Boot Which may Prevent a Crash Dump from Being Saved Service Alert <Document:2187794.1> - SunOS 4.x Binaries Fail to Run in Solaris 10 Branded Zones on Solaris 11.3.1.5.0 Through 11.3.12.4.0
23-Oct-2016 to 29-Oct-2016: No new or updated Service Alerts were released during this time period.
16-Oct-2016 to 22-Oct-2016: New: Service Alert <Document:2194147.1> - Solaris 10 syslogd(1M) with Certain Patches Installed may Report a Harmless I/O Error During System or Zone Shutdown Updated: Service Alert <Document:2133640.1> - Solaris Daylight Saving Time (DST) Updates for 2016 Service Alert <Document:2171450.1> - SPARC T7, S7 and M7 Systems May Experience Performance Issues on Newly Added Virtual CPUs (VCPUs)
09-Oct-2016 to 15-Oct-2016: New: Service Alert <Document:2192534.1> - On Solaris 11.3.1.5.0 or Later, Use of ZFS ARC may Cause System Panics and Performance Issues Leading to Hangs Updated: Service Alert <Document:2055578.1> - Solaris Cluster Utilities may Fail with Java Errors if the Default Java Version is Java SE JDK and JRE 8 Service Alert <Document:2133640.1> - Solaris Daylight Saving Time (DST) Updates for 2016
02-Oct-2016 to 08-Oct-2016: New: Service Alert <Document:2188787.1> - SPARC M5-32 and M6-32 Systems With System Firmware Versions 9.5.3 through 9.6.5.a May Experience Solaris Panic Due to Certain PCIe Fabric Errors Updated: Service Alert <Document:2188411.1> - After Running POST, SPARC T7/M7/S7 Systems With System Firmware 9.7.1.b, 9.7.1.c and 9.7.2.c may Cause Applications Utilizing DAX to Hang
25-Sep-2016 to 01-Oct-2016: New: Service Alert <Document:2187794.1> - SunOS 4.x Binaries Fail to Run in Solaris 10 Branded Zones on Solaris 11.3.1.5.0 Through 11.3.12.4.0 Service Alert <Document:2188411.1> - After Running POST, SPARC T7/M7/S7 Systems With System Firmware 9.7.1.b, 9.7.1.c and 9.7.2.c may Cause Applications Utilizing DAX to Hang
18-Sep-2016 to 24-Sep-2016: No new or updated Service Alerts were released during this time period.
11-Sep-2016 to 17-Sep-2016: Updated: Service Alert <Document:2167656.1> - Since 15th of July 2016, the Solaris 10 smpatch(1M) Service Fails with Error 500, as My Oracle Support (MOS) Now Requires SHA-2 Compatible SSL Certificates
04-Sep-2016 to 10-Sep-2016: New: Service Alert <Document:2179881.1> - SPARC T4/T5, M5/M6 or T7/S7/M7 Platforms Configured Explicitly for Cross-CPU Migration may Experience Memory Corruption in Oracle VM Server for SPARC Guest Domains and Solaris Kernel Zones Updated: Service Alert <Document:2161074.1> - Solaris 11 and ZFS Storage Appliance (ZFSSA) Software may Experience a System Panic in stmf_ts_xfer_restart() Service Alert <Document:2174622.1> - ZFS Storage Appliance (ZFSSA) Software and Solaris 11 Using SMB (smbd(1M)) may Experience a System Panic in smb_oplock_compute_max_level()
28-Aug-2016 to 03-Sep-2016: New: Service Alert <Document:2178184.1>- Solaris 11 and ZFS Storage Appliance (ZFSSA) Software Using SMB (smbd(1M)) With 'Oplocks' Enabled may Experience a Panic When Upgrading to SMB2.1 Service Alert <Document:2179100.1> - Solaris 11 (x86) and ZFS Storage Appliance (ZFSSA) Software may Experience a BAD TRAP Panic on Boot Which may Prevent a Crash Dump from Being Saved
21-Aug-2016 to 27-Aug-2016: New: Service Alert <Document:2174622.1> - ZFS Storage Appliance (ZFSSA) Software and Solaris 11 Using SMB (smbd(1M)) may Experience a System Panic in smb_oplock_compute_max_level() Updated: Service Alert <Document:1666311.1> - Solaris 11 and ZFS Storage Appliance Software (ZFSSA) Using the Network Data Management Protocol (NDMP) Will Fail to Backup Files and Directories With Inodes Greater Than 2^30
14-Aug-2016 to 20-Aug-2016: New: Service Alert <Document:2173984.1> - ZFS Storage Appliance (ZFSSA) Software and Solaris 11 Using SMB (smbd(1M)) May Experience a System Panic in list_remove() Updated: Service Alert <Document:2169435.1> - ZFS Storage Appliance (ZFSSA) Software 2013.1.6.0 (OS8.6.0) may Cause Disk Access Failure for Client Systems Using the iSCSI Networking Standard for Linking Data Storage Facilities, and has Been Withdrawn Service Alert <Document:2165712.1> - All ZFS Storage Appliance (ZFSSA) Software Network Data Management Protocol (NDMP) Backups Will Fail After a Configuration Backup Has Been Initiated Service Alert <Document:2169382.1> - For SPARC T4, T5 Series and SPARC M5-32/M6-32 Servers, System Firmware Version 8.9.5 and 9.6.5 May Cause System Panic (Firmware 8.9.5 and 9.6.5 are WITHDRAWN)
07-Aug-2016 to 13-Aug-2016: New: Service Alert <Document:2169946.1> - Solaris 10, Solaris 11 and ZFS Storage Appliance (ZFSSA) Software LDAP Clients may Cause a System Hang if the LDAP Servers are Specified by Name Rather Than Address Service Alert <Document:2171450.1> - SPARC T7, S7 and M7 Systems May Experience Performance Issues on Newly Added Virtual CPUs (VCPUs)
31-Jul-2016 to 06-Aug-2016: New: Service Alert <Document:2167656.1> - Since 15th of July 2016, the Solaris 10 smpatch(1M) Service Fails with Error 500, as My Oracle Support (MOS) Now Requires SHA-2 Compatible SSL Certificates Service Alert <Document:2167737.1> - Solaris 10, Solaris 11 and ZFS Storage Appliance (ZFSSA) Software may Experience a Deadlock in 'spa_config_enter' Service Alert <Document:2168080.1> - A New 'Firmware Check' Service in Solaris 11.3.10.5.0 Generates a FATAL Error Message and goes into Maintenance Mode if the System Firmware Version is not the Latest Release Service Alert <Document:2168715.1> - Solaris 10 SPARC Systems may Experience Page Coalesce Operation Performance Issues Even After Applying the Resolution Defined in Alert 2035701.1 Service Alert <Document:2168991.1> - Solaris 10, Solaris 11 and ZFS Storage Appliance (ZFSSA) Software May Experience Slow NFS Process Threads, Resulting in Poor ZFS I/O Performance Service Alert <Document:2169435.1> - ZFS Storage Appliance (ZFSSA) Software 2013.1.6.0 (OS8.6.0) may Cause Disk Access Failure for Client Systems Using the iSCSI Networking Standard for Linking Data Storage Facilities, and has Been Withdrawn Service Alert <Document:2169382.1> - For SPARC T4, T5 Series and SPARC M5-32/M6-32 Servers, System Firmware Version 8.9.5 and 9.6.5 May Cause System Panic (Firmware 8.9.5 and 9.6.5 are WITHDRAWN) Updated: Service Alert <Document:2161074.1> - Solaris 11 and ZFS Storage Appliance (ZFSSA) Software may Experience a System Panic in stmf_ts_xfer_restart() Service Alert <Document:2165712.1> - All ZFS Storage Appliance (ZFSSA) Software Network Data Management Protocol (NDMP) Backups Will Fail After a Configuration Backup Has Been Initiated
24-Jul-2016 to 30-Jul-2016: New: Service Alert <Document:2165712.1> - All ZFS Storage Appliance (ZFSSA) Software Network Data Management Protocol (NDMP) Backups Will Fail After a Configuration Backup Has Been Initiated Service Alert <Document:2166733.1> - Sun Storage 7310/7410 Storage Systems running ZFS Storage Appliance (ZFSSA) Software Version 2011.1.9.3 or Earlier with 100GB Readzilla SATA Disk Drives Require ZFSSA Upgrade to Avoid Drive Compatibility/Availability Issues Updated: Service Alert <Document:1982859.1> - Solaris Daylight Saving Time (DST) Updates for 2015
17-Jul-2016 to 23-Jul-2016: No new or updated Service Alerts were released during this time period.
10-Jul-2016 to 16-Jul-2016: New: Service Alert <Document:2161074.1> - Solaris 11 and ZFS Storage Appliance (ZFSSA) Software may Experience a System Panic in stmf_ts_xfer_restart() Updated: Service Alert <Document:2157019.1> - ZFS Storage Appliance (ZFSSA) Software and Solaris 11 Using SMB (smbd(1M)) may Experience a System Panic in crgetsid()
03-Jul-2016 to 09-Jul-2016: No new or updated Service Alerts were released during this time period.
26-Jun-2016 to 02-July-2016: New: Service Alert <Document:2157019.1> - ZFS Storage Appliance (ZFSSA) Software and Solaris 11 Using SMB (smbd(1M)) may Experience a System Panic in crgetsid()
19-Jun-2016 to 25-Jun-2016: Updated: Service Alert <Document:2059821.1> - Solaris 11.1.0.24.2 (or later) May Experience a BAD TRAP System Panic in lgrp_get_policy_flr()
12-Jun-2016 to 18-Jun-2016: New: Service Alert <Document:2150605.1> - Solaris 10 Systems With Patch 145899-03 (SPARC) or 145900-03 (x86), and Solaris 11 Systems With Solaris Volume Manager (SVM) Configured Disks may Experience SVM Replica Corruption When Swapping a Failed Disk Drive Used by the SVM Configuration
05-Jun-2016 to 11-Jun-2016: New: Service Alert <Document:2148136.1> - SPARC M7-8 and M-16 Systems May Experience a 'fpga-uc/TPM' Hardware Error When Updating to, or Downgrading From, Sun System Firmware 9.5.4a
29-May-2016 to 04-Jun-2016: No new or updated Service Alerts were released during this time period.
22-May-2016 to 28-May-2016: New: Service Alert <Document:2141147.1> - Solaris 11.3.7.5.0 Systems Using the Networking Services Library Functions rpcsec_gss(3NSL) may Experience a System Panic Updated: Service Alert <Document:2140485.1> - Oracle Solaris 11.3.7.5.0 Systems with the mpt_sas driver enabled may Experience a System Panic due to a NULL Pointer Dereference in vhci_mpapi_sync_lu_oid_list() or ddi_get_instance() Service Alert <Document:2141147.1> - Solaris 11.3.7.5.0 Systems Using the Networking Services Library Functions rpcsec_gss(3NSL) may Experience a System Panic
15-May-2016 to 21-May-2016: New: Service Alert <Document:2140485.1> - Oracle Solaris 11.3.7.5.0 Systems with the mpt_sas driver enabled may Experience a System Panic due to a NULL Pointer Dereference in vhci_mpapi_sync_lu_oid_list() or ddi_get_instance() Updated: Service Alert <Document:2067174.1> - Solaris 10, Solaris 11 and ZFS Storage Appliance (ZFSSA) Software may Intermittently Experience Transient Write Hangs if a Snapshot Destroy or Replication is in Progress
08-May-2016 to 14-May-2016: Updated: Service Alert <Document:2067174.1> - Solaris 10, Solaris 11 and ZFS Storage Appliance (ZFSSA) Software may Intermittently Experience Transient Write Hangs if a Snapshot Destroy or Replication is in Progress Service Alert <Document:2133737.1> - SPARC M5-32 and M6-32 Servers With Sun System Firmware 9.4.2.d, 9.4.2.e, 9.5.1.c, or 9.5.3 may Misidentify Faulty Components or Fail to Diagnose Faulty Components
01-May-2016 to 07-May-2016: New: Service Alert <Document:2133737.1> - Some ereports may be Incorrect on SPARC M5-32 and M6-32 Systems With Sun System Firmware 9.5.3 or Earlier Service Alert <Document:2133640.1> - Solaris Daylight Saving Time (DST) Updates for 2016
24-Apr-2016 to 30-Apr-2016: New: Service Alert <Document:2130478.1> - SPARC M5-32/M6-32 Systems With Sun System Firmware 9.5.3 or Earlier may Crash Unexpectedly While Running Service Alert <Document:2132072.1> - On FS1-2 Systems, Migration of Large Volume Extents May Lead to Controller Panics and Data Loss
17-Apr-2016 to 23-Apr-2016: New: Service Alert <Document:2128320.1> - Solaris 11.3.5.0.6 and Solaris 10 OpenSSL Patches 151914-03 (SPARC), 151915-03 (x86), 151912-04 (SPARC), and 151913-04 (x86) may Cause OpenSSL Connections to Fail During Handshake Phase Updated: Service Alert <Document:2074261.1> - ZFS Storage Appliance (ZFSSA) Software may Fail to Gather Analytics Data and the Browser User Interface (BUI) and Command Line Interface (CLI) may Slow Down or Hang Due to Insufficient Memory
10-Apr-2016 to 16-Apr-2016: No new or updated Service Alerts were released during this time period.
03-Apr-2016 to 09-Apr-2016: No new or updated Service Alerts were released during this time period.
27-Mar-2016 to 02-Apr-2016: New: Service Alert <Document:2120675.1> - Flash Storage System FS1-2 SAS Driver Failures May Lead to Loss of Data Access Service Alert <Document:2122334.1> - ZFS Storage Appliance (ZFSSA) Software may Experience a Pool Import Failure on Boot Up Following a Power-off With One or More Bad Log Devices
20-Mar-2016 to 26-Mar-2016: No new or updated Service Alerts were released during this time period.
13-Mar-2016 to 19-Mar-2016: Updated: Service Alert <Document:2046582.1> - Java 6u101, 7u85 and 8u51 and Later Releases Break Enterprise Manager Ops Center Agent Controller to Proxy Communication
06-Mar-2016 to 12-Mar-2016: No new or updated Service Alerts were released during this time period.
28-Feb-2016 to 05-Mar-2016: New: Service Alert <Document:2111676.1> - Solaris 11.2.8.4.0 and Later Releases may Cause a System Panic for Systems Using Third Party Kernel Drivers Updated: Service Alert <Document:2055578.1> - Solaris Cluster Utilities may Fail with Java Errors if the Default Java Version is Java SE JDK and JRE 8
21-Feb-2016 to 27-Feb-2016: New: Service Alert <Document:2105901.1> - OpenSSH Upgrade in Solaris 11.3.5.6.0 Changes ssh(1) Behavior for Systems not Using the Default SunSSH Service Alert <Document:2109480.1> - Solaris 11 Systems may Experience UFS File System Data Integrity Issues Which may Fail to be Reported Updated: Service Alert <Document:2055578.1> - Solaris Cluster Utilities may Fail with Java Errors if the Default Java Version is Java SE JDK and JRE 8
14-Feb-2016 to 20-Feb-2016: Updated: Service Alert <Document:1675249.1> - Collecting a Full Snapshot (dataset=full) on SPARC M5-32 or M6-32 Servers Running Sun System Firmware 9.2.0.b will Trigger Unplanned HOSTs Poweroff
07-Feb-2016 to 13-Feb-2016: Updated: Service Alert <Document:1952103.1> - Sun Storage Common Array Manager (CAM) Software Fails on Sun Storage 2540-M2 Arrays With IPV6 Enabled by the Manufacturer Using In-band Management Service Alert <Document:1960651.1> - ZFS Storage Appliance Software (ZFSSA) Network Data Management Protocol (NDMP) May Prevent Mounting of Shares During a Takeover or Renaming of Shares After an Aborted Backup Service Alert <Document:1955089.1> - Solaris 11 and ZFS Storage Appliance Software (ZFSSA) Network Data Management Protocol (NDMP) may Corrupt Previously Generated Backups When Using Oracle Secure Backup (OSB) 12.1 or Later Service Alert <Document:1951204.1> - Solaris 10, Solaris 11, and ZFS Storage Appliance Software (ZFSSA) Using the ixgbe(7D) Driver may Experience a NIC chip Reset and Report FMA Errors Service Alert <Document:1905327.1> - Solaris 10 and Solaris 11 x86 Systems May Panic Due to a Rare Race Condition in the HAT Layer Service Alert <Document:2067174.1> - Solaris 10, Solaris 11 and ZFS Storage Appliance (ZFSSA) Software may Intermittently Experience Transient Write Hangs if a Snapshot Destroy or Replication is in Progress
31-Jan-2016 to 06-Feb-2016: New: Service Alert <Document:2073313.1> - Firmware Upgrade to Alleviate Unrecoverable Read Errors on Certain 300GB, 600GB, 900G, and 1.2 TB Disk Drives Service Alert <Document:2102284.1> - eeprom Related Commands may Hang or Fail on SuperCluster Version 2.0 and 2.1 Systems Updated: Service Alert <Document:1664957.1> - Multiple Issues Reported with Storage Common Array Manager Software (CAM) 6.9.0
24-Jan-2016 to 30-Jan-2016: New: Service Alert <Document:2100341.1> - Solaris 11.0.0.2.0 through Solaris 11.3.3.6.0, Using snoop(1M), tshark(1) or tcpdump(1) for Capturing Packets Over IP Layer Devices may Cause Loss of TCP Connectivity or a System Panic Updated: Service Alert <Document:2057718.1> - ZFS Storage Appliance (ZFSSA) Software and Solaris 11 using SMB (smbd(1M)) May Experience Latency on Upgrade to SMB2.1 Service Alert <Document:2016654.1> - Systems Running ZFS Storage Appliance (ZFSSA) Software 2013.1.3.0 may Experience a System Panic in smb_oplock_hold()
17-Jan-2016 to 23-Jan-2016: New: Service Alert <Document:2098232.1> - Systems with a ZFS Root Filesystem Running Certain Solaris 10 patches or Solaris 11 SRUs may Hang if the Disks of the Root Pool Become Temporarily Unavailable
10-Jan-2016 to 16-Jan-2016: New: Service Alert <Document:2097483.1> - Oracle Virtual Machine (OVM) Server for SPARC Guest Domains Running Solaris 11.1.0.24.2 Through 11.2.7.4.0 may Panic While Memory Dynamic Reconfiguration (DR) is in Progress Updated: Service Alert <Document:2016654.1> - Systems Running ZFS Storage Appliance (ZFSSA) Software 2013.1.3.0 may Experience a System Panic in smb_oplock_hold() Service Alert <Document:2059712.1> - ZFS Storage Appliance (ZFSSA) Software Using SMB (smbd(1M)) may Experience a System Panic With the Message 'assertion failed: smb_open_attr_only.../smbsrv/smb_oplock.c' Service Alert <Document:2056144.1> - A Deadlock Condition in Solaris 11 and ZFS Storage Appliance (ZFSSA) Software may Cause the System to Experience a Hang or Panic Service Alert <Document:2057718.1> - ZFS Storage Appliance (ZFSSA) Software Using SMB (smbd(1M)) May Experience Latency on Upgrade to SMB 2.1
03-Jan-2016 to 09-Jan-2016: No new or updated Service Alerts were released during this time period.
27-Dec-2015 to 02-Jan-2016: No new or updated Service Alerts were released during this time period. (U.S. Holiday) To receive daily notifications of Service Alert releases (and other Knowledge Articles) Occurrence
Symptoms
Workaround
Patches
HistoryThis document is updated daily to report new and updated Service Alerts. 04-Jan-2016: Republished for New Year 2016 References<NOTE:1958236.1> - SERVICE ALERT WEEKLY SUMMARY REPORT (2014)<NOTE:1392057.1> - SUN ALERT WEEKLY SUMMARY REPORT (2011) <NOTE:1396364.1> - Get Proactive with Oracle Systems <NOTE:1279973.1> - Sun Alert Weekly Summary Report (2010) <NOTE:1611635.1> - SUN ALERT WEEKLY SUMMARY REPORT (2013) <NOTE:2093796.1> - SERVICE ALERT WEEKLY SUMMARY REPORT (2015) <NOTE:1517133.1> - SUN ALERT WEEKLY SUMMARY REPORT (2012) Attachments This solution has no attachment |
||||||||||||
|