Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1966721.1
Update Date:2015-02-02
Keywords:

Solution Type  Sun Alert Sure

Solution  1966721.1 :   SPARC M5-32 and M6-32 Servers running Sun System Firmware 9.3.0.c may Erroneously Mark Multiple CPU/Memory Units (CMUs) as Faulty When Starting Physical Domains  


Related Items
  • SPARC M5-32
  •  
  • Sun Software - Generic
  •  
  • SPARC M6-32
  •  
  • Sun Hardware - Generic
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun Alert
  •  
  • _Old GCS Categories>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • _Old GCS Categories>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  




In this Document
Description
Occurrence
Symptoms
Workaround
Patches
History
References


Applies to:

SPARC M5-32
SPARC M6-32
Sun Software - Generic
Sun Hardware - Generic
Information in this document applies to any platform.
SPARC
______________________________________



Date of Resolved Release: 02-Feb-2015
______________________________________

Description

After upgrading to Sun System Firmware release 9.3.0.c, SPARC M5-32 and M6-32 systems may report multiple faulty CPU/Memory Units (CMUs) when starting physical domains.

Occurrence

This issue can occur on the following systems:

  • SPARC M5-32 Servers with Firmware version 9.3.0.c (as delivered in patch 20034532)
  • SPARC M6-32 Servers with Firmware version 9.3.0.c (as delivered in patch 20034532)

Note: No other platforms are affected by this issue.

To determine the current firmware version on one of these servers, do the following:

   -> show -d properties /System/Firmware
    /System/Firmware
      Properties:
        system_fw_version = Sun System Firmware 9.3.0.c

Symptoms

If the described issue occurs, powering on a HOST may be completed, but CMU faults are reported with FMA diagnosis code SPT-8000-DH, similar to the following:

From ILOM command line:

    -> start /SP/faultmgmt/shell
    Are you sure you want to start /SP/faultmgmt/shell (y/n)? y

    faultmgmtsp> fmadm faulty

    2015-01-12/19:05:52 95a58ec8-b9b9-cb5f-871f-cb00d183a609 SPT-8000-DH Critical

    Problem Status    : open
    Diag Engine       : fdd 1.0
    System
    Manufacturer   : Oracle Corporation
    Name           : SPARC M6-32
    Part_Number    : 32763918+1+1
    Serial_Number  : AK00221282

    ----------------------------------------
    Suspect 1 of 1
    Fault class  : fault.chassis.voltage.fail
    Certainty    : 100%
    Affects      : /SYS/CMU12
    Status       : faulted

    FRU
       Status            : faulty
       Location          : /SYS/CMU12
       Manufacturer      : OEM
       Name              : Assy CMU
       Part_Number       : 7070507
       Revision          : 01
       Serial_Number     : 465769T+1422FE02T6
       Chassis
          Manufacturer   : Oracle Corporation
          Name           : SPARC M6-32
          Part_Number    : 32763918+1+1
          Serial_Number  : AK00221282

    2015-01-13/15:36:23 c43e0fa6-dfc0-4709-c335-c5fb01ff80a9 SPT-8000-DH Critical

    Problem Status    : open
    Diag Engine       : fdd 1.0
    System
    Manufacturer   : Oracle Corporation
    Name           : SPARC M6-32
    Part_Number    : 32763918+1+1
    Serial_Number  : AK00221282

    ----------------------------------------
    Suspect 1 of 1
    Fault class  : fault.chassis.voltage.fail
    Certainty    : 100%
    Affects      : /SYS/CMU8
    Status       : faulted

    FRU
       Status            : faulty
       Location          : /SYS/CMU8
       Manufacturer      : OEM
       Name              : Assy CMU
       Part_Number       : 7070507
       Revision          : 01
       Serial_Number     : 465769T+1403FE025H
       Chassis
          Manufacturer   : Oracle Corporation
          Name           : SPARC M6-32
          Part_Number    : 32763918+1+1
          Serial_Number  : AK00221282


    -> show /SYS/CMU12 fault_state requested_config_state current_config_state

    /SYS/CMU12
     Properties:
     fault_state = Faulted
     requested_config_state = Enabled
     current_config_state = Enabled

Workaround

This issue is addressed in the following firmware releases:

  • Sun System Firmware version 9.3.0.f or later (as delivered in patch 20229461 or later)

For the latest information on firmware upgrades for the above systems, reference the following documents:

  • <Document:1540816.1> "SPARC M5-32 and M6-32 Servers: Firmware Image Software Version Matrix Information"
  • <Document:1558958.2> "Information Center: SPARC M5-32 and SPARC M6-32 Servers"

Patches

 <SUNPATCH:20229461>

History

02-Feb-2015: Document released, status is Resolved

Internal Section: Comments:

This regression was caused by the putback for bug 17222441

Questions regarding this document should be addressed to
sunalertpublication_us_grp@oracle.com and copy the
responsible engineer/submitter listed below.

Internal Contributor/Submitter: David.Lafko@Oracle.Com, Marcel.Widjaja@oracle.com, stephane.dutilleul@oracle.com
Internal Eng Responsible Engineer:  hanh.nguyen@oracle.com
Oracle Knowledge Analyst: jeff.folla@oracle.com
Internal Eng Business Unit Group: Systems RPE
Internal Associated SRs: 3-10131946091, 3-10065718751, 3-10106600651, 3-10122781521, 3-10025521341, 3-10066420501, 3-10095008051, 3-10130064461, 3-10179742451
Internal Resolution Patches: 20229461
Reviewer (approved by):

References


<BUG:20243896> - VOLTAGE-UCR-GHI/VNW_SENSE-VSB_SENSE/OV_WARN ON VARIOUS CMUS WHEN STARTING HOST