![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||
Solution Type Sun Alert Sure Solution 1966721.1 : SPARC M5-32 and M6-32 Servers running Sun System Firmware 9.3.0.c may Erroneously Mark Multiple CPU/Memory Units (CMUs) as Faulty When Starting Physical Domains
In this Document
Applies to:SPARC M5-32SPARC M6-32 Sun Software - Generic Sun Hardware - Generic Information in this document applies to any platform. SPARC ______________________________________ Date of Resolved Release: 02-Feb-2015 ______________________________________ DescriptionAfter upgrading to Sun System Firmware release 9.3.0.c, SPARC M5-32 and M6-32 systems may report multiple faulty CPU/Memory Units (CMUs) when starting physical domains. OccurrenceThis issue can occur on the following systems:
Note: No other platforms are affected by this issue. -> show -d properties /System/Firmware /System/Firmware Properties: system_fw_version = Sun System Firmware 9.3.0.c SymptomsIf the described issue occurs, powering on a HOST may be completed, but CMU faults are reported with FMA diagnosis code SPT-8000-DH, similar to the following: -> start /SP/faultmgmt/shell Are you sure you want to start /SP/faultmgmt/shell (y/n)? y faultmgmtsp> fmadm faulty 2015-01-12/19:05:52 95a58ec8-b9b9-cb5f-871f-cb00d183a609 SPT-8000-DH Critical Problem Status : open Diag Engine : fdd 1.0 System Manufacturer : Oracle Corporation Name : SPARC M6-32 Part_Number : 32763918+1+1 Serial_Number : AK00221282 ---------------------------------------- Suspect 1 of 1 Fault class : fault.chassis.voltage.fail Certainty : 100% Affects : /SYS/CMU12 Status : faulted FRU Status : faulty Location : /SYS/CMU12 Manufacturer : OEM Name : Assy CMU Part_Number : 7070507 Revision : 01 Serial_Number : 465769T+1422FE02T6 Chassis Manufacturer : Oracle Corporation Name : SPARC M6-32 Part_Number : 32763918+1+1 Serial_Number : AK00221282 2015-01-13/15:36:23 c43e0fa6-dfc0-4709-c335-c5fb01ff80a9 SPT-8000-DH Critical Problem Status : open Diag Engine : fdd 1.0 System Manufacturer : Oracle Corporation Name : SPARC M6-32 Part_Number : 32763918+1+1 Serial_Number : AK00221282 ---------------------------------------- Suspect 1 of 1 Fault class : fault.chassis.voltage.fail Certainty : 100% Affects : /SYS/CMU8 Status : faulted FRU Status : faulty Location : /SYS/CMU8 Manufacturer : OEM Name : Assy CMU Part_Number : 7070507 Revision : 01 Serial_Number : 465769T+1403FE025H Chassis Manufacturer : Oracle Corporation Name : SPARC M6-32 Part_Number : 32763918+1+1 Serial_Number : AK00221282 -> show /SYS/CMU12 fault_state requested_config_state current_config_state /SYS/CMU12 Properties: fault_state = Faulted requested_config_state = Enabled current_config_state = Enabled WorkaroundThis issue is addressed in the following firmware releases:
For the latest information on firmware upgrades for the above systems, reference the following documents:
Patches<SUNPATCH:20229461> History02-Feb-2015: Document released, status is Resolved Internal Section: Comments: This regression was caused by the putback for bug 17222441 References<BUG:20243896> - VOLTAGE-UCR-GHI/VNW_SENSE-VSB_SENSE/OV_WARN ON VARIOUS CMUS WHEN STARTING HOST Attachments This solution has no attachment |
||||||||||||||||||||||||
|