Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorageTek 6140 : Field Action Bulletins


FAB Synopsis Last Modified Date
1512680.1 FAB: Reactive: Seagate disk drive failures due to excessive idling at the same track after the drive updates its internal logs in System (non-user) tracks. 2017-04-14
1019884.1 Controller replacement in Sun StorageTek 6140 and Sun StorageTek 6540 Arrays may initiate a Crystal firmware upgrade on the other controller. 2017-05-30
1019709.1 FAB: Standard: Reactive: Firmware downgrades from 07.xx.xx.xx require special procedures and approval. 2017-10-06
1019584.1 Misaligned spring connectors on CSM200 midplanes can cause HDD signal integrity issues for StorageTek 5320/5220 and 6140 Controller trays and CSM200 Expansion trays. 2015-06-01
1019519.1 FCO A0288-1: Hardware: Sun StorageTek 6140 Family contains incorrect UL power supply label. 2010-11-12
1019312.1 FAB: Standard: Reactive: Disk arrays running firmware versions 6.60 and 7.10 cannot send automated alerts through SDP to the Sun Storage TSC. 2012-01-18
1019216.1 FAB: Standard: Reactive: Number of screw holes used for mounting CSM200 Drive Cage Midplane may not match the number of screw holes in the tray Chassis. 2013-10-11
1001315.1 4GB Tyco Cables Can Be Damaged If Not Properly Removed 2010-08-23
1000790.1 The Ethernet port on the StorageTek 25x0/61x0/6540 controllers may not work properly while attached to an Ethernet Switch port with auto-negotiation disabled. 2015-12-07
1000284.1 FAB: Standard: Reactive: Clarification of the cables used for establishing a serial connection to the STK6140 and STK25x0 arrays. 2015-03-02