Sun StorEdge 3310 SCSI Array : Field Action Bulletins


FAB Synopsis Last Modified Date
1512680.1 FAB: Reactive: Seagate disk drive failures due to excessive idling at the same track after the drive updates its internal logs in System (non-user) tracks. 2017-04-14
1017446.1 Sun StorEdge 3310/3510 Array may stop processing I/O when more than 2 hosts send SCCLI commands. 2017-11-16
1017358.1 Sun StorEdge 3310/3510/3511 controllers must be allowed to complete the firmware cross loading process during controller replacement. 2013-12-26
1001302.1 Important Sun Alert Documents Released For SE3310, SE3320, SE3510 And SE3511 Arrays. 2018-02-28
1000882.1 Sun StorEdge 3310 Arrays with firmware prior to 4.13 and CLI software prior to 2.1, and SAF-TE firmware prior to 1170, may experience downtime, drives offline, and inaccurate status reporting for components. 2017-10-06
1000862.1 SE3310/3510/3511 Arrays may experience a variety of issues if the SCSI I/O Timeout value is set too low 2013-07-12
1000682.1 Array performance degradation as a result of the cache changing to write-through. 2015-06-30
1000674.1 Sun StorEdge 3310 controller FRUs will not successfully upgrade from firmware version 3.66 to 4.13B in single controller configurations. 2010-08-25
1000227.1 StorADE versions earlier than 2.4.39.005 may misrepresent errors for array components, possibly causing unnecessary replacement of hardware. 2013-09-04