Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-75-2254075.1
Update Date:2018-05-24
Keywords:

Solution Type  Troubleshooting Sure

Solution  2254075.1 :   SL8500 - Use LEDs on the HBN Card and CLI Displays when Troubleshooting SSD & Interlock Issues  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Purpose
Troubleshooting Steps


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Purpose

Use LEDs on the HBN Card and CLI Displays when Troubleshooting SSD & Interlock Issues.

Troubleshooting Steps

There are two useful aids in troubleshooting interlock and safety door issues. The LEDs on the HBN card and the CLI command "safetyinterlock status".

The LEDs are shown in the Service Manual, and in the Installation Manual in Chapter 9, Figure 9-7. The LED information and the CLI command output are provided below and in the attached interlock and SSD service aid document along with a note regarding what to check.

Notes:

Verify your LED status first and see if they change when switches are activated/deactivated.

The HBN has LED's that denote the SSD switch and door interlock statuses, you can check these also with the front door open.

Manually toggle the switches and verify the state on the HBN card or CLI command. As you manually pull the SSD left or right you can verify the switch engagement and hear the switch toggle states.

Make sure a pawl that toggles an SSD switch is not stuck in the closed position. They can over shoot the switch and get stuck on the wrong side of the switch lever. Visually check the pawls, which are spring loaded, and verify they freely move.

If the HBN indicators are toggling but the CLI status display does not change for one or more switches, suspect an issue with the signal cables running along the right side of the inner wall on the floor of the SL8500.

LED Displays:

HBN LEDs

CLI command “safetyinterlock status” output example:

Note: “Success” does not mean the states are all good. It only means the command successfully executed.

SL8500> safetyinterlock status

requestId 375601

Attributes Barrier Door Left Closed false

Barrier Door Right Closed false

Barrier Door Switch Fault false

Doors have been opened false

Emergency Power Off false

Front Door Switch Fault false

Interlock Battery Low false

Left Door Open false

Left Ok To Open Led off

Left Service Mode Switch false

Left Wait To Open Led off

Library Active Led on

Library Service Request LED fast Blink

Right Door Open false

Right Ok To Open Led off

Right Service Mode Switch false

Right Wait To Open Led off

Robotics Disabled false

Service Mode Switch Fault false

Object
Done

Failure Count 0

Success Count 1

COMPLETED

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.