Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-75-1573932.1
Update Date:2015-03-31
Keywords:

Solution Type  Troubleshooting Sure

Solution  1573932.1 :   Exadata Troubleshooting: [DiskControllerPCIeSlotWidth] Requires: x8 Found: x4  


Related Items
  • Exadata X4-2 Hardware
  •  
  • Exadata X3-2 Hardware
  •  
  • Exadata Database Machine X2-2 Qtr Rack
  •  
  • Exadata X4-2 Quarter Rack
  •  
  • Exadata X3-2 Half Rack
  •  
  • Exadata Database Machine X2-8
  •  
  • Exadata Database Machine X2-2 Full Rack
  •  
  • Exadata X4-2 Half Rack
  •  
  • Exadata X3-2 Full Rack
  •  
  • Exadata Database Machine X2-2 Half Rack
  •  
  • Exadata X4-2 Full Rack
  •  
  • Exadata X3-2 Eighth Rack
  •  
  • Exadata Database Machine V2
  •  
  • Exadata X4-2 Eighth Rack
  •  
  • Exadata X3-2 Quarter Rack
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




Applies to:

Exadata X4-2 Half Rack - Version All Versions and later
Exadata X3-2 Hardware - Version All Versions and later
Exadata X3-2 Full Rack - Version All Versions and later
Exadata X3-2 Half Rack - Version All Versions and later
Exadata X3-2 Quarter Rack - Version All Versions and later
Information in this document applies to any platform.

Purpose

To provide troubleshooting steps when receiving the following warning:

[DiskControllerPCIeSlotWidth] Requires: x8 Found: x4

Troubleshooting Steps

After a reboot of a cell server or when running Exachk, you see the following WARNING from one of your cell servers:

[root@dm11cel11 tmp]# /opt/oracle.cellos/CheckHWnFWProfile
[WARNING] The hardware and firmware are not supported. See details below

[DiskControllerPCIeSlotWidth]
Requires:
x8
Found:
x4
[WARNING] The hardware and firmware are not supported. See details above

 

In order to determine if there is a true hardware fault:

1.  Perform a cold power cycle of the cell:

  • Shut down the cell OS
  • Remove the power cords from both power supplies
  • Wait 1 minute
  • Plug the power cords back in
  • Power up the server and cell OS

 

NOTE:  Please follow the steps in MOS Note Steps to shut down or reboot an Exadata storage cell without affecting ASM <Document 1188080.1> to prevent issues with ASM disks.

 

If this does not clear the WARNING, collect a sundiag report from the cell server - MOS Note Oracle Exadata Diagnostic Information required for Disk Failures <Document 761868.1> - and open a Service Request for review.

 

INTERNAL:  Please note that in SR 3-10152318977 this cold power cycle did not resolve the issue, but a reseat of the RAID card and disk cables to SAS expander did fix the problem.

References

<NOTE:1188080.1> - Steps to shut down or reboot an Exadata storage cell without affecting ASM
<NOTE:761868.1> - Oracle Exadata Diagnostic Information required for Disk Failures and some other Hardware issues
<BUG:14020761> - [DISKCONTROLLERPCIESLOTWIDTH] REQUIRES: X8 FOUND: X4