Asset ID: |
1-75-1416374.1 |
Update Date: | 2017-09-20 |
Keywords: | |
Solution Type
Troubleshooting Sure
Solution
1416374.1
:
T10000C - Diagnose Fan Failures / How to Acquire Replacement Fan Assemblies
Related Items |
- StorageTek T10000C Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Oracle Support personnel
Applies to:
StorageTek T10000C Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.
Purpose
Diagnose T10000C Rackmount Fan Problems and how to acquire replacement fan.
Troubleshooting Steps
The Cooling Fan Assembly installed in T10000C Drive unit may make noise.
Note - These fans are NOT part of the power supply. (For PS Fan issues, replace Power Supply.) It is a separate assembly mounted outside of the drive brick with in the tray.
If you suspect the Cooling Fan Assembly is noisy or not functioning do the following to isolate the problem
1. Open the Drive Tray & check if any cables are hitting fan blade.
2. For a noisy fan problem disconnected the Cooling Fan Assembly plug momentarily to check if noise goes
away.
If Fan is identified as faulty:
For the time being, please contact rob.wilber@oracle.com for spares.
Engineering and logistics are working to make this an order-able part.
The Fan Assembly FRU Part Numbers are listed below.
316084501 BRACKET ASSEMBLY,FAN,RMT RACK MOUNT
7046446 FAN ASSEMBLY, SL8500 FRU, FAN SL8500
7046447 FAN ASSEMBLY, SL3000 FRU, FAN SL3000
The EC number for this change is E0009097.
Attachments
This solution has no attachment