Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-75-1387918.1
Update Date:2018-01-08
Keywords:

Solution Type  Troubleshooting Sure

Solution  1387918.1 :   Sun Storage 7000 Unified Storage System: Resolving NDMP configuration issues  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Unified Storage
  •  




In this Document
Purpose
Troubleshooting Steps
 For locally attached tape drives
 - Check HBA
 - Ensure ZFS Storage Appliance can see the attached tape library/drives.
References


Applies to:

Sun ZFS Storage 7320 - Version All Versions and later
Sun Storage 7110 Unified Storage System - Version All Versions and later
Sun Storage 7210 Unified Storage System - Version All Versions and later
Oracle ZFS Storage ZS3-2 - Version All Versions and later
Oracle ZFS Storage ZS3-4 - Version All Versions and later
7000 Appliance OS (Fishworks)

Purpose

Checking and resolving ZFS Storage Appliance NDMP and tape system configuration issues.

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage ZFS Storage Appliance Community

Troubleshooting Steps

NDMP configuration issues on ZFS storage Appliance can happen during installation of the tape system, during configuration changes of the tape system, or during tape system failures. Check the following:

  • Ensure Host Bus Adapter (HBA) is installed in the correct PCIe slot.
  • Identify if ZFS storage appliance can see the attached tape library/drives.
  • Ensure the Data management Application (DMA), tape library and tape drives are supported.
  • Ensure DMA backup software has the correct configuration.

For locally attached tape drives

- Check HBA

To check HBA status, model and slot number.

BUI - Maintenance > Hardware
Click "Show Details" next to the head unit, then click "Slot"
Click "information" icon to show detailed HBA information.

The status icon is green when HBA is ok, grey when not present or amber when faulted.
For further details check the Online Help wiki:
https://<appliance-ip-address>:215/wiki/index.php/Maintenance:Hardware

ZS4-4 system support 16Gb FC HBA for connection to tape library/drives

ZS3-2 and ZS3-4 system support 8Gb and 16Gb FC HBA
Part Number 371-4325 2-port 8Gb FC HBA
Part Number 7023303 2-port 16Gb FC HBA

7x20 systems support 8GB FC HBA

7x10 older systems support the following HBAs

Part Number 371-4325 2-port 8Gb FC HBA
Part Number 375-3356-02 QLogic QLE2462L 4Gb FC HBA
Part Number 375-3357-05 LSI LSI22320SLE SCSI HBA

HBA details and slot location is available in ZFS Storage Appliance Online wiki help
https://<appliance-ip-address>:215/wiki/index.php/Installation:Overview

- Ensure ZFS Storage Appliance can see the attached tape library/drives.

Display the attached tape library and drives using:

BUI - Status > NDMP

o For Fibre Channel connected devices:

  • Check and resolve FC connectivity
  • FC switch zoning and port status if connected to FC SAN
  • Tape library and drives hardware and connectivity health check

o For Direct-attached SCSI connections:

  • Check and resolve cabling from SCSI HBA to tape library and drives
  • Ensure proper connection, terminator and 10 m cable length restriction.
  • Consult HBA and tape library/drive manuals


A matrix  of certified vendors, versions of supported backup software and connectivity types is available at the Application Integration Engineering website.

DMA backup software configuration for Oracle Secure Backup, Symantec Netbackup and EMC Networker is available in the NDMP Implementation Guide
Consult DMA backup software manuals for detail configuration and engage DMA vendor as required.


Back to NDMP troubleshooting resolution path Document 1387930.1.

References

APPLICATION INTEGRATION ENGINEERING WIKI: HTTPS://STBEEHIVE.ORACLE.COM/TEAMCOLLAB/WIKI/APPLICATION+INTEGRATION+ENGINEERING+%28AIE%29+-+ZFSSA
NDMP IMPLEMENTATION WHITEPAPER: HTTPS://STBEEHIVE.ORACLE.COM/CONTENT/DAV/ST/AMBERROADSUPPORT/DOCUMENTS/NDMP/NDMP-WHITEPAPER-192164.PDF

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback