Asset ID: |
1-75-1339416.1 |
Update Date: | 2017-09-21 |
Keywords: | |
Solution Type
Troubleshooting Sure
Solution
1339416.1
:
L-Series Libraries - Troubleshooting Tape Library Power Problem
Related Items |
- Sun StorageTek L180 Tape Library
- Sun StorageTek L20 Tape Library
- Sun StorageTek L700e Tape Library
- Sun Storage L60 (OEM) Tape Library
- Sun StorageTek L1400 Tape Library
- Sun StorageTek L80 Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Oracle Support personnel
Applies to:
Sun StorageTek L20 Tape Library - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage L60 (OEM) Tape Library - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek L80 Tape Library - Version Not Applicable and later
Sun StorageTek L700e Tape Library - Version Not Applicable and later
Sun StorageTek L1400 Tape Library - Version Not Applicable and later
Information in this document applies to any platform.
Purpose
L-Series Libraries - Troubleshooting Tape Library Power Problem.
Troubleshooting Steps
PROBLEM OVERVIEW: Library does not power up correctly
CONFIRM THE FAULT BY CHECKING:
Check status LEDs on library Op Panel and power supplies
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
-Check the power supply breaker
-Check that the power supply is seated properly
-Check the power cord is seated properly
-Check that the tape drives are seated properly
-Pull tape drives to see if breaker will stay up
-Pull power cable from source and check incoming power and phases
-Check for correct power coming into library
-If power supply still fails, replace FRU
-Record specific error code and messages associated with failure in case notes
-Record all relevant visual observations of error in case notes
-Record final fix in case notes
CONFIRM THE FIX BY:
Library will power up and initialize to ready state
NOTE: Under NO circumstances show tape drives be returned with Media still inside the drive. If a tape is stuck in a drive, contact the Tape Hardware Support team for instructions on how to remove the tape with an email to tapehw_ww@oracle.com include the SR/case number in the subject line of the email.
Attachments
This solution has no attachment