Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-75-1018190.1
Update Date:2014-03-11
Keywords:

Solution Type  Troubleshooting Sure

Solution  1018190.1 :   Sun StorEdge T3: loop card failures  


Related Items
  • Sun Storage T3 Array
  •  
  • Sun Storage T3+ Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Arrays>SN-DK: T3_6020_6120
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
229548


Applies to:

Sun Storage T3 Array - Version Not Applicable and later
Sun Storage T3+ Array - Version Not Applicable and later
All Platforms

Purpose

The purpose of this document is to validate the following symptoms and provide the most accurate fix:

- loop card disabled

- loop card offline

Troubleshooting Steps

NOTE: This is a sub-set of <Document: 1018272.1> Troubleshooting Sun StorEdge[TM] T3 Configuration.
This document will help with faulted loop cards based on similar "fru stat"output below:
LOOP    STATUS   STATE       MODE        CABLE1    LB  CABLE2    LB  TEMP
------  -------  ----------  -------     --------- --  --------- --  ----
u1l1    ready    enabled     master      -         -   installed 10  27
u1l2    ready     <strong>disabled</strong>     slave       -         -   installed 11  33
u2l1    ready    enabled     master      installed 10  -         -   27
u2l2    offline

 

1.  Enable loop card with "enable u#[1|2]" command.

storage-t3b:/:<3>enable u1|2

2.  Verify that the loop card is now ready and enabled with the "fru stat" command.

NOTE:  Wait about 1 minute before running "fru stat" as to allow the array to recover.

3.  If the loop card is still not ready-enabled, then replace loop card.

References


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.