PreviouslyPublishedAs 229548 Applies to:Sun Storage T3 Array - Version Not Applicable and laterSun Storage T3+ Array - Version Not Applicable and later All Platforms PurposeThe purpose of this document is to validate the following symptoms and provide the most accurate fix: - loop card disabled - loop card offline Troubleshooting StepsNOTE: This is a sub-set of <Document: 1018272.1> Troubleshooting Sun StorEdge[TM] T3 Configuration.
This document will help with faulted loop cards based on similar "fru stat"output below: LOOP STATUS STATE MODE CABLE1 LB CABLE2 LB TEMP ------ ------- ---------- ------- --------- -- --------- -- ---- u1l1 ready enabled master - - installed 10 27 u1l2 ready <strong>disabled</strong> slave - - installed 11 33 u2l1 ready enabled master installed 10 - - 27 u2l2 offline
1. Enable loop card with "enable u#[1|2]" command. storage-t3b:/:<3>enable u1|2 2. Verify that the loop card is now ready and enabled with the "fru stat" command. NOTE: Wait about 1 minute before running "fru stat" as to allow the array to recover.
3. If the loop card is still not ready-enabled, then replace loop card. ReferencesAttachments This solution has no attachment |
||||||||||||
|