PreviouslyPublishedAs 218994 Symptoms Hosts can not see targets Hosts zoned by port can not see targets Hosts can not see target while in Open Fabric Interop Mode Resolution One reason for this to occur is that the Interop Mode for the switch is set in Open Fabric 1.0 and zoning is done by Domain, Port. McData does not support Domain, Port zoning while in Open Fabric 1.0 Interoperability Mode. This can be confirmed in the <Document: 1015627.1> Product Information log file. Resolution Options
Additional Information McData Sphereon 4500 McData Sphereon 4400 McData Sphereon 4700 McData Sphereon 3232 McData Intrepid 6064 Director McData Intrepid 6140 Director Switch is in Open Fabric 1.0 Interop Mode and is doing Domain, Port based zoning. Interop Mode is for connecting switches in a heterogeneous vendor environment. If all of your switches in the fabric are McData switches, Open Fabric Mode is not suggested. McData Hosts can see drives if switch is bypassed Switch Zoning is correct Product McData Switch Previously Published As STKKB73956 Attachments This solution has no attachment |
||||||||||||
|