Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-75-1012962.1
Update Date:2017-02-02
Keywords:

Solution Type  Troubleshooting Sure

Solution  1012962.1 :   Sun Fire [TM] SF3800/SF4800/SF4810/SF6800 - E4900/E6900 - V1280/E2900 - Netra 1280/1290 : Troubleshooting Firmware Upgrade Failures Using "flashupdate"  


Related Items
  • Sun Fire 3800 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Fire 4810 Server
  •  
  • Sun Fire E6900 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Netra 1280 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-x8x0/Ex900
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  

PreviouslyPublishedAs
217759


Applies to:

Sun Fire E2900 Server - Version Not Applicable and later
Sun Fire E4900 Server - Version Not Applicable and later
Sun Netra 1290 Server - Version Not Applicable and later
Sun Netra 1280 Server - Version Not Applicable and later
Sun Fire V1280 Server - Version Not Applicable and later
All Platforms

Purpose

Description
In order to provide you the most accurate fix, we need you to validate that each statement under the symptoms below are true for your environment.
Symptoms

The symptoms which would lead to using this resolution path are:

  •   "flashupdate" does not start, gives an error, or does not complete.
  •   The system controller may have reset, and is now unresponsive.
  •   The installation or upgrade may seem to be corrupt, faulty or bad.
  •   The system controller may hang, pause, become unresponsive, or similar behavior during the upgrade process.


System Type and Configuration

  •   Sun Fire[TM] v1280
  •   Sun Fire[TM] E2900
  •   Netra[TM] 1280
  •   Netra[TM] 1290
  •   Sun Fire[TM] 3800 - Sun Fire[TM] E6900


Assumptions

  •   SC is able to communicate via the network

Troubleshooting Steps

Steps to Follow
The listed troubleshooting steps are ordered in the most appropriate sequence to isolate the issue and be certain about the related fix. Please do not skip a step.

It's always recommended that you use the serial console to manage flashupdate, where possible.

1. Verify that the patch has been downloaded to a host that is able to communicate to the system controller.

  •   The simplest way to confirm this is to telnet into the IP address of the SC from the host that contains the patch
  •   Reference Document: 1005873.1 Sun Fire[TM] 3800/4x00/4810/6x00 Systems: flashprom update shortcut


2. Verify that the downloaded firmware patch on the host is not corrupt.


  •   The latest patch matrix can be found here: Sun Fire[TM] 3800, 48x0, 6800, E2900, E4900, E6900, v1280 or Netra[TM] 1280 or 1290: Firmware Matrix (Doc ID 1332666.1)


3. Verify this is not a known permissions issue related to being root user.

  •   Reference Document: 1018210.1 Sun Fire[TM] Midframe Server:Symptom:Flashupdate fails when user is root No boards can be updated


4. Verify this is not a known permissions issue related to ftp login.

  •   Reference Document: 1003105.1 Sun Fire[TM] (3800-6800) FTP login failure while doing flashupdate on a System Controller


5. While capturing "script" data, confirm that another attempt to upgrade the firmware with flashupdate has failed.


  •   Reference Document: 1006281.1 5.17.x and 5.18.x firmware update procedure for Sun Fire[TM] midrange and entry-level midrange systems
  •   Reference Document: 1004222.1 How to setup console logging and obtain diagnostic data from different types of SPARC and X64 servers


6. Verify scripted output is available and collaborate with next level of support.




 

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in an appropriate
My Oracle Support Community - Oracle Sun Technologies Community.



Product
Sun Fire V1280 Server
Sun Fire E6900 Server
Sun Fire E4900 Server
Sun Fire E6900 Server
Sun Fire E2900 Server
Sun Fire 6800 Server
Sun Fire 4810 Server
Sun Fire 4800 Server
Sun Fire 3800 Server
Netra 1280 Server
Netra 1290 Server


References

<NOTE:1003105.1> - Sun Fire[TM] (3800-6800) FTP login failure while doing flashupdate on a System Controller
<NOTE:1004222.1> - How to setup console logging and obtain diagnostic data from different types of SPARC servers
<NOTE:1005873.1> - Sun Fire [TM] SF3800/SF4800/SF4810/SF6800 - E4900/E6900 - V1280/E2900, Netra 1280/1290 Server: flashprom update shortcut
<NOTE:1006281.1> - Firmware Download and update procedure for Sun Fire[TM] v1280, 3800, 4800, 4810, 6800, E2900, E4900, E6900, and Netra 1280, 1290 systems.
<NOTE:1018210.1> - Sun Fire[TM] Midframe Server:Symptom:Flashupdate fails when user is root-No boards can be updated
<NOTE:1332666.1> - Sun Fire[TM] 3800, 48x0, 6800, E2900, E4900, E6900, v1280 or Netra[TM] 1280, or 1290: Firmware Matrix