Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-75-1008255.1
Update Date:2018-03-20
Keywords:

Solution Type  Troubleshooting Sure

Solution  1008255.1 :   Sun Storage 35xx Arrays: How to Handle "Drive Recovered Error Reported" and Other Disk Drive Messages  


Related Items
  • Sun Storage 3510 FC Array
  •  
  • Sun Storage 3511 SATA Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Arrays>SN-DK: SE31xx_33xx_35xx
  •  

PreviouslyPublishedAs
211315


Applies to:

Sun Storage 3511 SATA Array - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 3510 FC Array - Version Not Applicable to Not Applicable [Release N/A]
All Platforms

Purpose

On the Sun Storage 351x FC Arrays, drive events such as: "Drive Recovered Error Reported" may appear. This does not necessarily mean the drive is bad and needs to be replaced. This document provides explanations for commonly reported disk messages.

For example :

*CHL:2 ID:3 Drive NOTIFY: Drive Recovered Error Reported (103)
*CHL:2 ID:3  Drive NOTIFY: Block Successfully Reassigned  0x1E02B40

 

Troubleshooting Steps


NOTE: This is a sub-set of <Document 1008190.1> Sun Storage 3000 Arrays: Troubleshooting Disk Failures.


When there is a drive error on the 351x array disk, the following event may be seen in the logs:

CHL:_ ID:_ SCSI Drive ALERT: Bad Block Encountered - Block_number (Sense_key Sense_code)

 Example:

StorEdge Array SN#XXXXXX CH2 ID6: SCSI Drive ALERT: bad block encountered (02h, 03h,11/00) SCSI Status:0x02 Sense Key:0x03 Sense Code:0x11 Sense Code Qualifier:0x00


This messages indicates a bad block was encountered in the specified hard drive. The RAID controller will ask the hard drive to retry the read or write command. If the host attempts a read to this location, a "media error" status may be returned:

[Primary] Warning

CHL:2 ID:11 Drive NOTIFY: Media Error Encountered - AA0BBCF (311)


If a write to the drive is attempted, the block may be re-allocated and the "recovered" message displayed.
The following event is generated when re-writes are attempted and bad blocks have been successfully reassigned:

[Primary] Warning

CHL:2 ID:3 Drive NOTIFY: Block Successfully Reassigned - 0x1E02B40


The following event is generated when Drive-side block reassignment failed. Drive will be considered as having media errors or failed:

CHL:_ ID:_ SCSI Drive ALERT: Block Reassignment Failed - Block_number (Sense_key Sense_code)


Example:

Oct 1 03:38:48 trdbd16 SUNWscsdMonitor[546]: [ID 994717 daemon.error]

[SUNWscsd 0x20B1E0C: Warning] Bad Block Encountered(Ch:2,Id:1).
Sector Number is 135927184. Informational message.

Oct 1 03:38:48 trdbd16 SUNWscsdMonitor[546]: [ID 979789 daemon.error]

[SUNWscsd 0x20B1E0F: Warning] Block Reassignment Failure(Ch:2,Id:1). Defective drive. Replace.

 
Eventually the event below may occur, indicating SCSI drive unrecoverable hardware error reported. The drive needs to be replaced at that time.

CHL:_ ID:_ SCSI Drive ALERT: Drive HW Error (Sense_key Sense_code)

 Example:

[Primary] Warning

CHL:2 ID:3 Drive ALERT: Drive HW Error (432)

 

Note - The three-digit code in parentheses provides additional information about the drive error.
The first of these three digits represents the SCSI Sense Key.
The remaining two digits represent the Additional Sense Code (ASC).



For more information about SCSI sense codes, refer to:
https://support.oracle.com/handbook_private/General/SCSI_Disk_Tr.html#SENSECODE

If a Bug is not applicable to the disk error(s) and these messages appear more frequently (about >5 a day and/or every day) then it is advisable to have the drive replaced to preserve data integrity and prevent performance degradation.
Also see : Doc ID 1006649.1 "Sun StorEdge[TM] 3000 Arrays: 3.2x and 4.x Firmware Differences in Handling Media Errors".

In some cases, "Drive Recovered Error Reported (117)" messages could be related to an issue with
Fujitsu drives as discussed in <BUG:15373181>

 

Do you still have questions?  You can use My Oracle Support Communities.  Communities put you in touch with industry professionals like yourself.  They are monitored by Oracle support engineers, so you can expect reliable and correct answers.  Ask questions and see what others are asking about in the Disk Storage 2000, 3000, 6000 RAID Arrays & JBODs Community.

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback