Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-75-1008191.1
Update Date:2014-02-28
Keywords:

Solution Type  Troubleshooting Sure

Solution  1008191.1 :   Sun StorageTek 33x0 SCSI Array: Troubleshooting SCSI Devices from the Operating System  


Related Items
  • Sun Storage 3310 Array
  •  
  • Sun Storage 3320 SCSI Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Arrays>SN-DK: SE31xx_33xx_35xx
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
211250


Applies to:

Sun Storage 3320 SCSI Array - Version Not Applicable and later
Sun Storage 3310 Array - Version Not Applicable and later
All Platforms

Purpose

 
Description
Troubleshooting Sun Storedge 3000 array SCSI Devices from the Operating System

Troubleshooting Steps



Steps to Follow
Please validate that each troubleshooting step below is true for your environment. The steps will provide instructions or a link to a document, for validating the step and taking corrective action as necessary. The steps are ordered in the most appropriate sequence to isolate the issue and identify the proper resolution. Please do not skip a step.

Step 1 - Identify which device path is not seen by looking at format or /var/adm/messages.This will be needed in step 2.

Example:

/devices/pci@1f,4000/pci@5/scsi@4

Step 2 - Verify the HBA can be seen from the OS

Refer to <Document 1005314.1> Sun StorageTek 33x0 SCSI Array: How to verify SCSI HBA Connectivity

Step 3 - Verify StorEdge array hardware and configuration is optimal.

Refer to <Document 1005313.1> Sun Storage 3000 Arrays: Troubleshooting Configuration Problems.

Step 4 - Verify lun setting within the sd.conf file.

Refer to Editing the sd.conf file in  Appendix D2, of the Sun StorEdge 3000 Family Installation, Operation, and Service Manual

Step 5 - Solaris only supports Veritas DMP for SCSI multipathing on 33X0 arrays, To verify Multipathing is enabled correctly.

Refer to <Document 1011302.1> "Verifying DMP Health" for VxDMP

 

At this point, if you have validated that each troubleshooting step above is true for your environment, and the issue still exists,further in-depth troubleshooting is required. Please provide supporting data and open a Service Request.

Product
Sun StorageTek 3310 SCSI Array
Sun StorageTek 3320 SCSI Array



Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback