Solution Type Troubleshooting Sure Solution 1008191.1 : Sun StorageTek 33x0 SCSI Array: Troubleshooting SCSI Devices from the Operating System
PreviouslyPublishedAs 211250 Applies to:Sun Storage 3320 SCSI Array - Version Not Applicable and laterSun Storage 3310 Array - Version Not Applicable and later All Platforms Purpose Troubleshooting Steps
Step 1 - Identify which device path is not seen by looking at format or /var/adm/messages.This will be needed in step 2. Example: /devices/pci@1f,4000/pci@5/scsi@4 Step 2 - Verify the HBA can be seen from the OS Refer to <Document 1005314.1> Sun StorageTek 33x0 SCSI Array: How to verify SCSI HBA Connectivity Step 3 - Verify StorEdge array hardware and configuration is optimal. Refer to <Document 1005313.1> Sun Storage 3000 Arrays: Troubleshooting Configuration Problems. Step 4 - Verify lun setting within the sd.conf file. Refer to Editing the sd.conf file in Appendix D2, of the Sun StorEdge 3000 Family Installation, Operation, and Service Manual Step 5 - Solaris only supports Veritas DMP for SCSI multipathing on 33X0 arrays, To verify Multipathing is enabled correctly. Refer to <Document 1011302.1> "Verifying DMP Health" for VxDMP
At this point, if you have validated that each troubleshooting step above is true for your environment, and the issue still exists,further in-depth troubleshooting is required. Please provide supporting data and open a Service Request. Product Attachments This solution has no attachment |
||||||||||||
|