Solution Type  Troubleshooting Sure

Solution  1005458.1 :   Troubleshooting Sun Fire[TM] V1280/E2900 and Netra[TM] 1280/1290 Server Firmware upgrade fails when using lom -G  


Related Items
  • Sun Netra 1290 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Netra 1280 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Exx00
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  

PreviouslyPublishedAs
207581


Applies to:

Sun Fire V1280 Server - Version Not Applicable and later
Sun Fire E2900 Server - Version Not Applicable and later
Sun Netra 1290 Server - Version Not Applicable and later
Sun Netra 1280 Server - Version Not Applicable and later
All Platforms

Purpose

This article addresses and attempts to troubleshoot upgrade failures of Sun Fire[TM] V1280/E2900 and Netra[TM] 1280/1290 Server Firmware, when using lom -G.

Troubleshooting Steps

Symptoms

 

  • The System Controller (SC) may have reset, and is now unresponsive
  • The Solaris[TM] command lom -G gives an error, or does not complete
  • The installation or upgrade may seem to be corrupt, faulty, bad
  • The system may hang, pause, become unresponsive, or similar behavior during the upgrade process.

System Type and Configuration

  • Sun Fire[TM] v1280
  • Sun Fire[TM] E2900
  • Netra[TM] 1280
  • Netra[TM] 1290

Assumptions

  • The System Controller (SC) is up and the domain is up and running.



Steps to Follow
Please validate that each troubleshooting step below is true for your environment. Each step will provide instructions or a link to a document for validating the step and taking corrective action as necessary. The steps are ordered in the most appropriate sequence to isolate the issue and identify the proper resolution. Please do not skip a step.

1. Verify the error message is not  Programming LOM Failed with Error: Resource Temporarily Unavailable 

 

  • This issue is resolved by resetting the SC and reissuing the  lom -G  command.

  •  See Document: 1010536.1 Sun Fire[TM] V1280/E2900 and Netra[TM] 1280 Servers: Programming LOM Failed with Error: Resource Temporarily Unavailable

 

2. Verify the system controller is not hung.


3.  Verify user is logged onto the system containing the firmware patch as root.

For navigation between shells, reference the Sun Fire Midrange Systems Platform Administration Manual


4. Verify the system has lom packages installed

  • Use the pkginfo command to confirm that SUNWlom installed, for example:

#pkginfo |grep lom
system      SUNWlomm                         LOMlite manual pages
system      SUNWlomr                         LOMlite driver (root)
system      SUNWlomu                         LOMlite Utilities (usr)
  • Reference Document: 1004868.1 SunFire[TM] V1280/E2900 and Netra[TM] 1280: Lights Out Management (LOM) packages are missing


5. Verify that the downloaded firmware patch is not corrupt.

  • Reference the firmware patch matrix document Document: 1010756.1 Sun Fire[TM] Mid-Range Servers ScApp Features and Requirements Matrix


6. Verify that the files have the appropriate permissions set:

This is an example of a system with the  proper permissions set.  

#ls -l /
total 21354
-rwxr-xr-x   1 root     root       45704 Nov  3 05:28 Install.info
-r--r--r--   1 root     root       14684 Nov  2 11:47 LEGAL_LICENSE.TXT
-rw-r--r--   1 root     root       13773 Nov  8 14:40 README.114527-04
-rwxr-xr-x   1 root     root        2055 Oct 21 07:38 copyright
-rwxr-xr-x   1 root     root     1115699 Oct 21 07:29 lw8cpu.flash
-rwxr-xr-x   1 root     root      421307 Oct 21 07:38 lw8pci.flash
-rwxr-xr-x   1 root     root         284 Nov  7 09:53 patchinfo
-rwxr-xr-x   1 root     root       12895 Sep 26 16:37 readme_520_doc.css
-rwxr-xr-x   1 root     root        1490 Sep 26 16:37 readme_520_doc.html
-rwxr-xr-x   1 root     root     1148406 Oct 21 07:25 sgcpu.flash
-rwxr-xr-x   1 root     root      469579 Oct 21 07:34 sgiowci.flash
-rwxr-xr-x   1 root     root      355252 Oct 21 07:34 sgpci.flash
-rwxr-xr-x   1 root     root      695496 Sep 26 08:53 sgrtos.flash
-rwxr-xr-x   1 root     root     6541898 Oct 21 07:38 sgsc.flash


7. While capturing  script  data, confirm that another attempt to upgrade the firmware with lom -G by using the absolute path has failed.

  • Reference  Document: 1003856.1  Sun Fire[TM] 1280/2900 server: How to flash firmware with lom -G
  • Reference Document: 1004222.1 How to setup console logging and obtain diagnostic data from different types of SPARC(R) and X64 servers

 

8. At this point, if you have validated that each troubleshooting step above is true for your environment, and the issue still exists, further troubleshooting is required.  Verify scripted output is available and open a Service Request to Oracle Support.



 

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in an appropriate
My Oracle Support Community - Oracle Sun Technologies Community.




lom -G, firmware, upgrade, normalized

References

<NOTE:1003856.1> - Sun Fire[TM] v1280/E2900 and Netra[TM] 1280/1290 server: How to flash firmware with lom -G [Video]
<NOTE:1004222.1> - How to setup console logging and obtain diagnostic data from different types of SPARC servers
<NOTE:1004868.1> - SunFire[TM] V1280, E2900 and Netra[TM] 1280, 1290: Lights Out Management (LOM) packages are missing
<NOTE:1010536.1> - Sun Fire[TM] V1280, E2900, Netra[TM] 1280, and 1290 Servers: Programming LOM Failed with Error: Resource Temporarily Unavailable
<NOTE:1010756.1> - Sun Fire[TM] Mid-Range Servers ScApp Features and Requirements Matrix
<NOTE:1003661.1> - How to recover when a Sun Fire[TM]E2900, V1280 or Netra[TM] 1280 has an incompatible RTOS and ScApp