![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Troubleshooting Sure Solution 1005458.1 : Troubleshooting Sun Fire[TM] V1280/E2900 and Netra[TM] 1280/1290 Server Firmware upgrade fails when using lom -G
PreviouslyPublishedAs 207581 Applies to:Sun Fire V1280 Server - Version Not Applicable and laterSun Fire E2900 Server - Version Not Applicable and later Sun Netra 1290 Server - Version Not Applicable and later Sun Netra 1280 Server - Version Not Applicable and later All Platforms PurposeThis article addresses and attempts to troubleshoot upgrade failures of Sun Fire[TM] V1280/E2900 and Netra[TM] 1280/1290 Server Firmware, when using lom -G. Troubleshooting StepsSymptoms
System Type and Configuration
Assumptions
2. Verify the system controller is not hung.
3. Verify user is logged onto the system containing the firmware patch as root. For navigation between shells, reference the Sun Fire Midrange Systems Platform Administration Manual 4. Verify the system has lom packages installed
#pkginfo |grep lom system SUNWlomm LOMlite manual pages system SUNWlomr LOMlite driver (root) system SUNWlomu LOMlite Utilities (usr)
5. Verify that the downloaded firmware patch is not corrupt.
6. Verify that the files have the appropriate permissions set: This is an example of a system with the proper permissions set. #ls -l / total 21354 -rwxr-xr-x 1 root root 45704 Nov 3 05:28 Install.info -r--r--r-- 1 root root 14684 Nov 2 11:47 LEGAL_LICENSE.TXT -rw-r--r-- 1 root root 13773 Nov 8 14:40 README.114527-04 -rwxr-xr-x 1 root root 2055 Oct 21 07:38 copyright -rwxr-xr-x 1 root root 1115699 Oct 21 07:29 lw8cpu.flash -rwxr-xr-x 1 root root 421307 Oct 21 07:38 lw8pci.flash -rwxr-xr-x 1 root root 284 Nov 7 09:53 patchinfo -rwxr-xr-x 1 root root 12895 Sep 26 16:37 readme_520_doc.css -rwxr-xr-x 1 root root 1490 Sep 26 16:37 readme_520_doc.html -rwxr-xr-x 1 root root 1148406 Oct 21 07:25 sgcpu.flash -rwxr-xr-x 1 root root 469579 Oct 21 07:34 sgiowci.flash -rwxr-xr-x 1 root root 355252 Oct 21 07:34 sgpci.flash -rwxr-xr-x 1 root root 695496 Sep 26 08:53 sgrtos.flash -rwxr-xr-x 1 root root 6541898 Oct 21 07:38 sgsc.flash 7. While capturing script data, confirm that another attempt to upgrade the firmware with lom -G by using the absolute path has failed.
8. At this point, if you have validated that each troubleshooting step above is true for your environment, and the issue still exists, further troubleshooting is required. Verify scripted output is available and open a Service Request to Oracle Support.
To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in an appropriate
My Oracle Support Community - Oracle Sun Technologies Community.
References<NOTE:1003856.1> - Sun Fire[TM] v1280/E2900 and Netra[TM] 1280/1290 server: How to flash firmware with lom -G [Video]<NOTE:1004222.1> - How to setup console logging and obtain diagnostic data from different types of SPARC servers <NOTE:1004868.1> - SunFire[TM] V1280, E2900 and Netra[TM] 1280, 1290: Lights Out Management (LOM) packages are missing <NOTE:1010536.1> - Sun Fire[TM] V1280, E2900, Netra[TM] 1280, and 1290 Servers: Programming LOM Failed with Error: Resource Temporarily Unavailable <NOTE:1010756.1> - Sun Fire[TM] Mid-Range Servers ScApp Features and Requirements Matrix <NOTE:1003661.1> - How to recover when a Sun Fire[TM]E2900, V1280 or Netra[TM] 1280 has an incompatible RTOS and ScApp Attachments This solution has no attachment |
||||||||||||
|