![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Troubleshooting Sure Solution 1002708.1 : Sun Ultra[TM] 45 serial port spec
PreviouslyPublishedAs 203714 Applies to:Sun Ultra 25 Workstation - Version Not Applicable and laterSun Ultra 45 Workstation - Version Not Applicable and later All Platforms PurposeThe purpose of this document is to address a slight discrepency found within the Sun Ultra[TM] 45 and Sun Ultra[TM] 25 Workstations Installation Guide 819-1891-11 Troubleshooting StepsGoalThe guide specifies that the serial ports on Ultra 25 and 45 are RS-432. This is wrong. FixThe correct interface is RS-232 Attachments This solution has no attachment |
||||||||||||
|