Solution Type  Technical Instruction Sure

Solution  2401143.1 :   [E5MS 46.5]Configuration of maximum permissible inactivity period  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
  •  


Customer wants to configure and increase the maximum permissible inactivity period (in minutes)

In this Document
Goal
Solution


Created from <SR 3-17432909881>

Applies to:

Oracle Communications EAGLE (Software) - Version E5-MS 46.5 and later
Information in this document applies to any platform.

Goal

Query is to increase the idle user's client session timeout value
 

Solution

Below procedure provided to configure login restriction for user Lockout time and Inactivity period:-

1. Go to the directory "/Tekelec/WebNMS/conf".

 2. Create a backup copy of the original config file.
  eg.
  # cp clientparameters.conf clientparameters.bak-

 3. Open the config file with vi editor and in "clientparameters.conf" and edit the following lines as desired.

  ALLOWED_IDLE_TIME_BEFORE_LOCKOUT=""
  ALLOWED_IDLE_TIME_BEFORE_TERMINATION=""

  a). ALLOWED_IDLE_TIME_BEFORE_LOCKOUT : lockout time default value is 30 minutes. Set this parameter set to zero for user session do not lock out.
  b). ALLOWED_IDLE_TIME_BEFORE_TERMINATION: inactivity time default value is 60 minutes.

4. Save and exit.

5. Restart the E5MS service for the new config to be effective.


 