![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2401143.1 : [E5MS 46.5]Configuration of maximum permissible inactivity period
Customer wants to configure and increase the maximum permissible inactivity period (in minutes) In this Document
Created from <SR 3-17432909881> Applies to:Oracle Communications EAGLE (Software) - Version E5-MS 46.5 and laterInformation in this document applies to any platform. GoalQuery is to increase the idle user's client session timeout value SolutionBelow procedure provided to configure login restriction for user Lockout time and Inactivity period:- 1. Go to the directory "/Tekelec/WebNMS/conf".
2. Create a backup copy of the original config file. eg. # cp clientparameters.conf clientparameters.bak- 3. Open the config file with vi editor and in "clientparameters.conf" and edit the following lines as desired. ALLOWED_IDLE_TIME_BEFORE_LOCKOUT="" ALLOWED_IDLE_TIME_BEFORE_TERMINATION="" a). ALLOWED_IDLE_TIME_BEFORE_LOCKOUT : lockout time default value is 30 minutes. Set this parameter set to zero for user session do not lock out. b). ALLOWED_IDLE_TIME_BEFORE_TERMINATION: inactivity time default value is 60 minutes. 4. Save and exit. 5. Restart the E5MS service for the new config to be effective.
Attachments This solution has no attachment |
||||||||||||||
|