Solution Type  Technical Instruction Sure

Solution  2401052.1 :   Eagle: VLR-PROF Table Change Requires Deleting Entry From VLR-ROAMING Table First - E3609 Cmd Rej: A Reference Of This Entry Exists In VLR Roaming TBL  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution
References


Created from <SR 3-17012440921>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.6 and later
Tekelec

Goal

VLR-PROF table change requires deleting entry from VLR-ROAMING table first

chg-vlr-prof command does not allows to modify the vlr to whitelist/blacklist or graylist with error E3609 - a reference of this entry exists in vlr roaming table.

> chg-vlr-prof:vlr=3399:filter=whitelist

  eagle 18-03-05 05:30:40 EST EAGLE 46.6.0.0.0-73.16.0
  chg-vlr-prof:vlr=3399:filter=whitelist
  Command entered at terminal #18.
;

  eagle 18-03-05 05:30:40 EST EAGLE 46.6.0.0.0-73.16.0
  CHG-VLR-PROF: MASP A - Command Aborted
;
E3609 Cmd Rej: A reference of this entry exists in VLR roaming tbl


> rtrv-vlr-roaming

  eagle 18-03-05 05:31:59 EST EAGLE 46.6.0.0.0-73.16.0
  rtrv-vlr-roaming
  Command entered at terminal #18.
;

Command Accepted - Processing
  eagle 18-03-05 05:31:59 EST EAGLE 46.6.0.0.0-73.16.0

  OLD_VLR NEW_VLR TIME
  95604 77777 10
  447 358 180
  aaaaa 1234 230
  aaaaa 77777 230
  358 447 180
  66666 3399 5
  3399 66666 5
  3399 9166 20
  9166 3399 20
  3399 7777 20

  VLR-ROAMING table is (10 of 1000) 1% full.

;
Command Executed


 

Solution

Bug 28036464 is opened to address this issue.
 

References

<BUG:28036464> - CDS: VLR-PROF TABLE CHANGE REQUIRES DELETING ENTRY FROM VLR-ROAMING TABLE FIRST