![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2401030.1 : Eagle: SYSTOT-SFAPP Measurement Report Shows GTT Action def_sfapp But This Cannot Be Seen In Configuration
In this Document
Created from <SR 3-17012441004> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 46.6 and laterTekelec GoalSYSTOT-SFAPP Measurement report shows gtt (Global Title Translation) action def_sfapp but this cannot be seen in configuration CLLI SWREL RPTDATE RPTIME TZ RPTTYPE RPTPD IVALDATE IVALSTART IVALEND NUMENTIDS
eagle EAGLE 46.6.0.0.0-73.16.0 3/5/2018 4:31:30 EST STP SYSTEM TOTAL MEASUREMENTS ON SFAPP LAST 3/5/2018 4:00:00 4:30:00 5 STATUS GTT ACTION SFAPPSUCC SFAPPFAIL SFAPPERROR1 SFAPPERROR2 K sfapp 4 1 0 0 K test 0 0 0 0 K test2 0 0 0 0 K sfapp1 0 0 0 0 K def_sfapp 0 0 0 0 > rtrv-gttact:act=sfapp eagle 18-03-05 06:42:14 EST EAGLE 46.6.0.0.0-73.16.0 rtrv-gttact:act=sfapp Command entered at terminal #18. ; Command Accepted - Processing eagle 18-03-05 06:42:14 EST EAGLE 46.6.0.0.0-73.16.0 ACTID ACTION DEFACTID NDGT UIMREQD ---------------------------------------------------------------- sfapp sfapp FALLBACK ALL on SCFADDR = 9999999999 FAILACTID = disc1 HLRADDR = USECDPA test sfapp FALLBACK ALL off SCFADDR = 1234567879 FAILACTID = FALLBACK HLRADDR = TCAPPARM TT = 10 test2 sfapp FALLBACK ALL on SCFADDR = 666 FAILACTID = disc1 HLRADDR = USECDPA sfapp1 sfapp FALLBACK ALL off SCFADDR = 9999999999 FAILACTID = FALLBACK HLRADDR = TCAPPARM TT = 10 GTT-ACT table is (7 of 2000) 1% full. ; Command Executed
SolutionThis is working as designed. The last entry is defined for default SFAPP GTT action which will be labelled as "def_sfapp" GTT action in the measurements table Attachments This solution has no attachment |
||||||||||||||
|