Solution Type  Technical Instruction Sure

Solution  2401024.1 :   Feature limitation with SFAPP  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-17002215191>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.5 and later
Information in this document applies to any platform.

Goal

Feature limitation with SFAPP.

Solution

Following feature will not work with SFAPP

  1. GSM MAP screening -  SFAPP card will not support EGMS.
  2. HLR Routing feature (GFLEX) on the same node. GFLEX interaction may be required for the ATI messages that need to be routed to the correct HLR for messages that do not have HLR address in the CdPA. This can be done by routing the message via EAGLE mate using the C-Links.

 