Solution Type  Technical Instruction Sure

Solution  2399328.1 :   SBC Changes SDP, But Does Not Change o-line Index  


Related Items
  • Acme Packet 6300
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Session Delivery Network>SN-SND: Acme Service Provider
  •  




In this Document
Goal
Solution


Created from <SR 3-17106970331>

Applies to:

Acme Packet 6300 - Version S-Cz7.3.0 to S-Cz7.3.0 [Release S-Cz7.0]
Information in this document applies to any platform.

Goal

 SBC changes SDP, but does not change o-line index

Solution

Configuring below parameter.
media-manager -> media-manager -> options +unique-sdp-id

"unique-sdp-id" -- This is required for the SBC to track the session id and version number in the SDP. Without it the SDP just forwards what it receives.