![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2399328.1 : SBC Changes SDP, But Does Not Change o-line Index
In this Document
Created from <SR 3-17106970331> Applies to:Acme Packet 6300 - Version S-Cz7.3.0 to S-Cz7.3.0 [Release S-Cz7.0]Information in this document applies to any platform. GoalSBC changes SDP, but does not change o-line index SolutionConfiguring below parameter. "unique-sdp-id" -- This is required for the SBC to track the session id and version number in the SDP. Without it the SDP just forwards what it receives. Attachments This solution has no attachment |
||||||||||||||
|