Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2397399.1
Update Date:2018-05-14
Keywords:

Solution Type  Technical Instruction Sure

Solution  2397399.1 :   OCEEMS (E5-MS) : Configure Login Restriction For User Lockout Time and Inactivity Period/Idle Time.  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
  •  




In this Document
Goal
Solution


Created from <SR 3-17372240321>

Applies to:

Oracle Communications EAGLE (Software) - Version E5-MS 46.2 and later
Information in this document applies to any platform.

Goal

To configure the following timers in E5-MS GUI access:-
  - Lockout time
  - Inactivity period
  - Maximum period of active GUI session.
 

Solution

Below procedure on how to configure login restriction for user Lockout time and Inactivity period for E5-MS GUI access:-

  1. Logon E5-MS server command line as admin or root user.

  2. Go to the directory "/Tekelec/WebNMS/conf".

  3. Create a backup copy of the original config file.

      Example:-

  # cp clientparameters.conf clientparameters.bak



  4. Open the config file "clientparameters.conf" and edit the following lines.

  ALLOWED_IDLE_TIME_BEFORE_LOCKOUT="30"
  ALLOWED_IDLE_TIME_BEFORE_TERMINATION="60"


      a). ALLOWED_IDLE_TIME_BEFORE_LOCKOUT : lockout time default value is 30 minutes. Set this parameter to zero for user session do not lock out.

      b). ALLOWED_IDLE_TIME_BEFORE_TERMINATION: inactivity time default value is 60 minutes.

  5. Save and exit.

  6. Restart the E5MS service.

      Example:-

    # service e5msService <stop/start>

 

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.