Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2395109.1
Update Date:2018-05-07
Keywords:

Solution Type  Technical Instruction Sure

Solution  2395109.1 :   OCEEMS Not Able To Perform Threshold Configurations In OCEEMS  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
  •  




In this Document
Goal
Solution


Created from <SR 3-16907058651>

Applies to:

Oracle Communications EAGLE (Hardware) - Version E5-MS 46.2 and later
Tekelec

Goal

We are not able to do any changes in Threshold configurations under Link Utilization in OCEEMS.

Where as I tried doing changes in other tabs like link utilization and on demand polling those i am able to perform.

ERROR - You are not authorized for this module - Please contact OCEEMS administrator.

Solution

Following entry is not present in the license file:
893-0414-01 E5-MS MEASUREMENT BASED THRESHOLD ALARMS

Kindly contact Oracle Sales to help you with the new license file.

 