Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2394718.1
Update Date:2018-05-28
Keywords:

Solution Type  Technical Instruction Sure

Solution  2394718.1 :   How to disable Smart Install Service on Cisco switch?  


Related Items
  • Exadata X5-2 Hardware
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Exadata X3-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  




In this Document
Goal
Solution


Created from <SR 3-17254238423>

Applies to:

Exadata X5-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

How to disable smart install on cisco switch
 

Solution

Verify if Smart Install Service is enabled or not on the Cisco Switch:

adm01>show vstack config | inc Role
Role: Client (SmartInstall enabled)

To Disable:

Steps should be
Switch> enable
Switch> <enter password if required>
Switch# config t
Switch(config)# no vstack
Switch(config)# exit

Please note the "no vstack" command does not persist across reload due to Cisco defect CSCvd99197 and Cisco recommends to upgrade IOS to 15.2.4E6 to address this issue.


 