![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2394332.1 : T10000D - Media/Density Reporting on SLConsole Cartridge Summary reports T10000D as T10000C tape.
In this Document
Created from <SR 3-17119377381> Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions and laterStorageTek T10000D Tape Drive - Version All Versions and later Sun StorageTek SL3000 Modular Library System - Version All Versions and later Information in this document applies to any platform. GoalOnly T10KD drives are used in the SL8500 or SL3000 tape library. Why does the library's Cartridge Summary show T10000C in the Media column if the media has only been written to using T10000D drives? Shouldn't it show the density of the media as T10000D? SolutionThe SL8500 and SL3000 Cartridge Summary on the SLConsole will only show Media as T10000C for all T2 media whether the tape was written by T10000C or T10000D. The library defaults to reporting T10000C for all T2 media. There is nothing from the library perspective that will show T10000D for media/density because the library does not know what type of drive wrote on the T2 media. Attachments This solution has no attachment |
||||||||||||||
|