Solution  2393888.1 :   Eagle: One association of USSD01 server was down with Customer Oracle STP.  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-17312343031>

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 46.3 to EAGLE 46.5 [Release EAGLE 46.0]
Tekelec

Goal

 One association of USSD01 server  was  down with Customer Oracle STP.

Solution

 s-xxxxx IS-ANR Restrict ACCESS ------------------------> OUTPUT OF rept-stat-rte Displays POINT CODE OF USSD server is down
OBSERVATION=2 rept-stat-dstn:
s-xxxxx IS-ANR Restrict ACCESS ------------------------> OUTPUT OF rept-stat-dstn Displays POINT CODE OF USSD server is down
OBSERVATION=3 rept-stat-trbl:display=timestamp
1172.0312 * DPC s-xxxxx DPC is restricted ------------------------> OUTPUT OF rept-stat-trbl:display=timestamp Displays POINT CODE OF USSD server is in restricted state.
18-04-18 15:24:06

 

 

 TAC Suggested Customer for getting  the USSD server to restart the application on USSD server.
After Application restart at USSD issue was resolved and both the association were stable.

 

 