Solution Type Technical Instruction Sure Solution 2386169.1 : How to Replace Old Adapters/Cables on ExAP Ports for SMxG Cards in Order to Support 1 Gbps/Full Duplex?
In this Document
Created from <SR 3-17222193051> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 46.5 and laterInformation in this document applies to any platform. GoalHow to Replace Old Adapters/Cables on ExAP Ports for SMxG Cards in Order to Support 1 Gbps/Full Duplex? SolutionTo replace cables and adapters on ExAP Ports for SMxG Cards (SCCP/SMxG) cards in order to support 1 Gbps/Full Duplex follow next steps: 1) Enter the following command to determine the number of SCCP/SMxG cards that are IS-NR. rept-stat-sccp
2) Enter the following command to verify current status for involved SCCP/ SMxG card.. rept-stat-card:loc=xxxx
3) Enter the following command to remove the SCCP/SMxG card from service. inh-card:loc=xxxx
4) Remove current cables/adapters for involved SCCP/SMxG card at Eagle backplane and EPAP’s switch. 5) Insert DSM’s card adapters with P/N 830-1104-XX. 6) Connect cables with P/N 830-1174-XX [Shielded Straight Through Cable (CAT-5)] at Eagle backplane and ExAP’s switch. 7) Enter the following command to return the SCCP/SMxG card into service alw-card:loc=xxxx
8) Verify that SCCP/SMxG card is IS-NR and its IPLNK/ports are UP: rept-stat-card:mode=full:loc=xxxx
9) Once DSM card is IS-NR and its IPLNK/ports are UP, repeat steps from 2 to 8 for next SCCP/SMxG card. References<NOTE:1597048.1> - Oracle Documentation LinksAttachments This solution has no attachment |
||||||||||||||||
|