Asset ID: |
1-71-2382753.1 |
Update Date: | 2018-04-11 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2382753.1
:
How to check Big Data Appliance (BDA) firmware versions
Related Items |
- Big Data Appliance X6-2 Hardware
- Big Data Appliance X5-2 Hardware
- Big Data Appliance Hardware
- Big Data Appliance X4-2 Hardware
- Big Data Appliance X3-2 Hardware
- Big Data Appliance X7-2 Hardware
|
Related Categories |
- PLA-Support>Sun Systems>x86>Engineered Systems HW>SN-x64: BDA
|
In this Document
Applies to:
Big Data Appliance X5-2 Hardware - Version All Versions to All Versions [Release All Releases]
Big Data Appliance X6-2 Hardware - Version All Versions to All Versions [Release All Releases]
Big Data Appliance X4-2 Hardware - Version All Versions to All Versions [Release All Releases]
Big Data Appliance Hardware - Version All Versions to All Versions [Release All Releases]
Big Data Appliance X3-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
This document shows how to check the firmware versions on the various Big Data Appliance rack components.
Solution
Note: "fwupdate" command is available in BDA v4.1.0 and later. For earlier images, use the alternate method provided.
Note: The output from the "fwupdate" commands shown below can be quite long on several single lines. It may be shown on your screen wrapped onto the next line. Maximizing your browser window and/or viewing in a landscape mode may help your viewing experience.
Check the server node ILOM/SP firmware
This example shows the ILOM version is v4.0.0.20 r120817 and the BIOS version is 42017100
ssh to the node
[root@bdanode ~]# fwupdate list sp_bios==================================================SP==================================================ID Product Name System Firmware Version ILOM Version BIOS/OBP Version Fallback Boot Version XML Support-------------------------------------------------------------------------------------------------------------------------------sp ORACLE SERVER X7-2L - v4.0.0.20 r120817 42017100 - N/A[root@bdanode ~]# exit
Alternate method via ssh to the ilom
-> version
SP firmware 4.0.0.20
SP firmware build number: 120817
SP firmware date: Sun Aug 20 16:43:13 PDT 2017
SP filesystem version: 0.3.170104
-> show /SYS/MB/BIOS fru_version
/SYS/MB/BIOS
Properties:
fru_version = 42017100
-> exit
Check the controller firmware (SAS HBA, IB HCA)
The sample below shows the HBA version is 4.720.00-8253 from package 24.19.0-0060 and the HCA version is 2.11.1280
ssh to the node
[root@bdanode ~]# fwupdate list controller
==================================================
CONTROLLER
==================================================
ID Type Manufacturer Model Product Name FW Version BIOS Version EFI Version FCODE Version Package Version NVDATA Version XML Support
--------------------------------------------------------------------------------------------------------------------------------------------------------
c0 SAS LSI Logic 0x00ce Avago MegaRAID SAS 9361-1 4.720.00-8253 6.34.01.0 06.22.02.02 4.19.08.00 - - N/A
c1 HDC Intel 0xa182 0x4867 - - - - - - N/A
c2 IB Mellanox 0x1003 Sun InfiniBand Dual Port 2.11.1280 - - - - - N/A
c3 NET Intel 0x1533 Intel(R) I210 Gigabit Net - - 80000681 - N/A
[root@bdanode ~]# exit
Alternate method for the HBA
[root@bdanode ~]# /opt/MegaRAID/storcli/storcli64 /c0 show | grep FW
FW Package Build = 24.19.0-0060
FW Version = 4.720.00-8253
[root@bdanode ~]# exit
Alternate two step method for the HCA
#1 Identify the device id
#2 Query the device
[root@bdanode ~]# lspci | grep InfiniBand
46:00.0 InfiniBand: Mellanox Technologies MT27500 Family [ConnectX-3]
[root@bdanode ~]# mstflint -d 46:00.0 q | grep FW
FW Version: 2.11.1280
[bdanode ~]# exit
Check the disk firmware (HDD and SSD)
This example shows all HDDs have firmware version A374 and the SSD firmware is 0112. Not all version of BDA have SSDs.
ssh to the node
[root@bdanode ~]# fwupdate list disk
==================================================
CONTROLLER
==================================================
ID Type Manufacturer Model Product Name FW Version BIOS Version EFI Version FCODE Version Package Version NVDATA Version XML Support
---------------------------------------------------------------------------------------------------------------------------------------------------------
c0 SAS LSI Logic 0x00ce Avago MegaRAID SAS 9361-1 4.720.00-8253 6.34.01.0 06.22.02.02 4.19.08.00 - - N/A
DISKS
===============
ID Manufacturer Model Chassis Slot Type Media Size(GiB) FW Version XML Support
-----------------------------------------------------------------------------------------------
c0d0 HGST H7210A520SUN010T - 0 sas HDD 9124 A374 N/A
c0d1 HGST H7210A520SUN010T - 1 sas HDD 9124 A374 N/A
c0d2 HGST H7210A520SUN010T - 2 sas HDD 9124 A374 N/A
c0d3 HGST H7210A520SUN010T - 3 sas HDD 9124 A374 N/A
c0d4 HGST H7210A520SUN010T - 4 sas HDD 9124 A374 N/A
c0d5 HGST H7210A520SUN010T - 5 sas HDD 9124 A374 N/A
c0d6 HGST H7210A520SUN010T - 6 sas HDD 9124 A374 N/A
c0d7 HGST H7210A520SUN010T - 7 sas HDD 9124 A374 N/A
c0d8 HGST H7210A520SUN010T - 8 sas HDD 9124 A374 N/A
c0d9 HGST H7210A520SUN010T - 9 sas HDD 9124 A374 N/A
c0d10 HGST H7210A520SUN010T - 10 sas HDD 9124 A374 N/A
c0d11 HGST H7210A520SUN010T - 11 sas HDD 9124 A374 N/A
==================================================
CONTROLLER
==================================================
ID Type Manufacturer Model Product Name FW Version BIOS Version EFI Version FCODE Version Package Version NVDATA Version XML Support
-------------------------------------------------------------------------------------------------------------------------------------
c1 HDC Intel 0xa182 0x4867 - - - - - - N/A
DISKS
===============
ID Manufacturer Model Chassis Slot Type Media Size(GiB) FW Version XML Support
-----------------------------------------------------------------------------------------------------------
c1d0 INTEL SSDSCKJB15 - - sata SSD 140 0112 N/A
c1d1 INTEL SSDSCKJB15 - - sata SSD 140 0112 N/A
[root@bdanode ~]# exit
Check the InifiBand spine and leaf switch firmware
These examples show all three switches have version 2.2.7-1
ssh to the spine switch
login as: ilom-admin
Hostname: bdasw-ib1
-> version
SP firmware 2.2.7-1
SP firmware build number: 118629
SP firmware date: Fri Jun 9 13:38:19 CEST 2017
SP filesystem version: 0.0.3
-> exit
ssh to the leaf1 switch
login as: ilom-admin
Hostname: bdasw-ib2
-> version
SP firmware 2.2.7-1
SP firmware build number: 118629
SP firmware date: Fri Jun 9 14:23:48 CEST 2017
SP filesystem version: 0.0.3
-> exit
ssh to the leaf2 switch
login as: ilom-admin
Hostname: bdasw-ib3
-> version
SP firmware 2.2.7-1
SP firmware build number: 118629
SP firmware date: Fri Jun 9 14:23:48 CEST 2017
SP filesystem version: 0.0.3
-> exit
Check the Cisco Catalyst C4948E ethernet switch firmware (used before BDA X7-2)
The example below show the system image is bootflash:cat4500-ipbasek9-mz.150-2.SG9.bin
ssh to the Cisco switch
login as: admin
bdasw-ip>show version
Cisco IOS Software, Catalyst 4500 L3 Switch Software (cat4500-IPBASEK9-M), Version 15.0(2)SG9, RELEASE SOFTWARE (fc2)
[snip]
System image file is "bootflash:cat4500-ipbasek9-mz.150-2.SG9.bin"
[snip]
bdasw-ip> exit
Check the Cisco Nexus 93108TC ethernet switch firmware (used starting in BDA X7-2)
The example below shows BIOS version version 07.59 and NXOS version version 7.0(3)I5(2)
ssh to the Cisco switch
login as: admin
bdasw-ip# show version
[snip]
Software
BIOS: version 07.59
NXOS: version 7.0(3)I5(2)
BIOS compile time: 08/26/2016
NXOS image file is: bootflash:///nxos.7.0.3.I5.2.bin
NXOS compile time: 2/16/2017 8:00:00 [02/16/2017 12:03:27]
bdasw-ip# exit
Check the PDU firmware
This example shows the PDU firmware is V2.07.
Note: ssh is only supported on Enhanced PDU's which shipped with X5-2 and later. For earlier systems, access the PDU via the web browser and select the "Module Info" button. The version will be v1.0x. v2.x firmware is not supported on v1.x PDU's.
ssh to the PDU
login as: admin
Welcome to Oracle PDU 'bdanode-pduX.company.com'
Login OK - Admin rights!
pducli->get pdu_firmware_version
pducli->pdu_firmware_version=V2.07 - 08.11.2016
pducli->exit
https:// browser to the PDU
References
<NOTE:1528190.1> - Firmware Upgrade Policy and Factory Ship Versions for Oracle Big Data Appliance Sun Fire X4270 M2, X3-2, X4-2,X5-2,X6-2 and X7-2
Attachments
This solution has no attachment