Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2380998.1
Update Date:2018-04-05
Keywords:

Solution Type  Technical Instruction Sure

Solution  2380998.1 :   M12-2 Memory Configuration Rules  


Related Items
  • Fujitsu SPARC M12-2S
  •  
  • Fujitsu SPARC M12-2
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Fujitsu M12
  •  




In this Document
Goal
Solution


Applies to:

Fujitsu SPARC M12-2S - Version All Versions to All Versions [Release All Releases]
Fujitsu SPARC M12-2 - Version All Versions to All Versions [Release All Releases]
SPARC

Goal

 This document describes the correct memory configuration for a M12-2 and a M12-2S

Solution

CPU/Memory configuration rules:

- Memory Size
- DIMMs:8/16/32/64GB
- 32 Slots per BB

 M12-2/M12-2S: Allowed DIMM combination connected to the same CPU chip is as follows:

– No rule difference between non memory-mirror users and memory-mirror users
- 64GB memory is not used in combination with the 8GB or 16GB


DIMMs combinations installed GRP-A:   8GB/16GB   (Cannot use 64GB in combination)
                                        GRP-A:   32GB         (Can use 64GB in combination)

DIMMs combinations installed GRP-B:   8GB/16GB   (Cannot use 64GB in combination)
                                        GRP-B:   32GB         (Can use 64GB in conbination)

 

NOTE: In the following description, 10A-13A means 10A, 11A, 12A, 13A

– M12-2/M12-2S:
  CMUL
        – CPU#0: CMUL/MEM#00A-07A, 00B-07B

 CMUU
       – CPU#0: CMUU/MEM#00A-07A, 00B-07B

 

CPU/Memory configuration rule

M12-2/M12-2S: 1 CPU configuration has 16 DIMM slots.

 

The below image shows a 1 CPU configuration where the CMUL memory is populated

  • Bank A should be populated first (light green area)
  • Bank B next (blue area)

 


.

 

M12-2/M12-2S: 2 CPU configuration has 32 DIMM slots:

 On M12-2/M12-2S, CMUU (CPU module upper) is optional
– CPU on CMUU is fixed to CMUU. To install 2nd CPU, CMUU should be mounted
– To install more than 16 DIMMs, CMUU must be mounted

 

 

This image shows a 2 CPU configuration where CMUU and CMUL memory are populated

  • CMUL should be populated first, bank A       (light green area)
  • CMUU bank A should be populated next       (yellow area)
  • CMUL bank B should be next                      (blue area)
  • CMUU bank B the last slots to be populated  (dark green area)

 

 

 

 