Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2380324.1
Update Date:2018-04-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  2380324.1 :   Eagle: Are Mixed Link Types Allowed In A Linkset?  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution
References


Created from <SR 3-16911988961>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.3 and later
Tekelec

Goal

Customer has mixed type of links in the linkset cchndel1 .

--------------------------------------------------------

rtrv-ls:lsn=cchndel1

tekelecstp 18-02-21 14:27:20 IST EAGLE 46.3.1.0.0-68.30.1
rtrv-ls:lsn=cchndel1
Command entered at terminal #21.
;

Searching link set table on disk - please wait...
Command Accepted - Processing
tekelecstp 18-02-21 14:27:20 IST EAGLE 46.3.1.0.0-68.30.1

L3T SLT GWS GWS GWS
LSN APCN (SS7) SCRN SET SET BEI LST LNKS ACT MES DIS SLSCI NIS
lsnname xxxx none 1 2 no C 8 off off off no off

SPCN CLLI TFATCABMLQ MTPRSE ASL8 GSMSCRN
---------------- zzzzz 4 --- --- off

SLSOCBIT SLSRSB RANDSLS ITUTFR ICNIMAP OGNIMAP
none 3 off off none none

IPSG IPGWAPC GTTMODE CGGTMOD PCT CHGMTP3OPC
no no AdvCdPA,CdPA no off on

LOC LINK SLC TYPE IPLIML2
4111 A 0 IPLIMI M2PA
4211 A 1 IPLIMI M2PA

L2T PCR PCR E1 E1
LOC LINK SLC TYPE SET BPS ECM N1 N2 LOC PORT TS
4307 B 2 LIME1 26 1.984M BASIC ---- ------ 4307 6 1
5211 A 3 LIME1 26 1.984M BASIC ---- ------ 5211 1 1
5305 A 4 LIME1 26 1.984M BASIC ---- ------ 5305 1 1
5305 B 5 LIME1 26 1.984M BASIC ---- ------ 5305 2 1
5307 A 6 LIME1 26 1.984M BASIC ---- ------ 5307 1 1
5307 B 7 LIME1 26 1.984M BASIC ---- ------ 5307 2 1

SAPCI
x-xxx-x

SAPCN
x-xxxxx

Link set table is (496 of 1024) 48% full.

;
Command Executed

--------------------------------------------------------------------

 

We have to validate if the abnormalities detected in their network may be due to wrong configuration of the links in the linkset. 

 

Solution

Combining IP links and low-speed links in same linkset will limit bandwidth availability and scalability. Creating dedicated linksets for IP links and low-speed links also can cause load sharing issues (load sharing across more than two linksets).
 

-- The linkset "lsnname" has 8 links out which 6 are TDM HSL and remaining 2 links are IPLIMI. It is not a recommended configuration to have combination of two different link types in the same linkset.

This is recommended only during the migration.

Change the configuration of the linkset to have only IP links or only TDM links.

 

-- Each IPLIM card can contain multiple links and support up to 4000 TPS. There is currently no way to assign TPS limits associated with IPLIM cards or links as we do for IPSG and IPGW.

Due to this reason there cannot be a guaranteed bandwidth for a IPLIM link, hence it is recommended to migrate to IPSG M2PA links from IPLIMI M2PA links.

References

<NOTE:2258988.1> - Congestion Levels At Signalling Links