![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2379006.1 : Eagle: How To Correct The BIOS Time In EPAPs
In this Document
Created from <SR 3-16968012371> Applies to:Oracle Communications EAGLE (Software) - Version EPAP 16.0 and laterTekelec GoalHow to correct the BIOS time in EPAPs? SolutionThe BIOS time reset usually happens when the card is re-seated, since E5-APPB doesn't have a battery to preserve the date. We need to manually set the BIOS Date/Time with current Date/Time in GMT. ==================================================================================== 1. While using Putty, make sure the keyboard selection is VT100+ 2. Do a console login to the server as root 3. Verify the complete system status 4. Reboot the server #reboot 5. Press "DEL" key when the system reboots. This will take you to BIOS screen. 6. In the MAIN screen use arrow keys to navigate to Date and Time 7. Set the correct date and time, save and exit. ====================================================================================