Solution Type  Technical Instruction Sure

Solution  2376386.1 :   DSR SOAM GUI Diameter Common Dashboard Slow in Updating Values of Different Counters  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Goal
Solution


Created from <SR 3-16992070138>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.3.0 and later
Tekelec

Goal

In the SOAM GUI -> Diameter COMMON -> Dashboard
the values for different counters do not update quickly enough.


 

Solution

Perform the httpd process restart and after that, the values will updating correctly.
On active SOAM:

sudo service httpd restart

 

 

 